Specifications
Audio Gain (Kenwood)
Example
ICOM : Command for AF gain is 14010000 to 14010255. Syntax = 1401**** (4 digits required)
with Min=0 and Max=255
KENWOOD : Command for AF gain is AG0000 to AG0255. Syntax is AG0*** (3 digits required) with
Min=0 and Max=255
Sending a command to the Band Decoder
Sending a direct command to the band decoder is possible provided:
The format of the command is the format defined for the band decoder you are using
(Parallel port = 8bits, Com port = ASCII or HEX).
The command to the band decoder is inserted inside square brackets [xxxx] (no space
before or after the square brackets)
Command sent to a parallel band decoder
Page 147