Specifications

1
1.1 Specifications
Control Panel Specifications
PC1575 (standard option): one low current PGM output
and one low current PGM output/input.
PC1575 (2-wire smoke option): one low current PGM
output and one high current PGM output/input.
Flexible Zone Configuration:
Six fully programmable zones
Seven Access Codes: five User, one Master and a
second Master code
Normally Closed, Single EOL, Double EOL
2-wire Smoke Zone or Auxiliary Zone
21 Zone Types, 6 Programmable Zone Options
Audible Alarm Output:
Supervised Bell Output (current limited at 3 amps), 12V
DC
Steady or Pulsed Output
EEPROM Memory:
Does not lose programming or system status on
complete AC and Battery failure
Programmable Outputs:
One programmable voltage output and one
programmable voltage output/input; 30 programmable
options
PC1575 (standard option):
PGM1 = one low current (50mA) PGM output
PGM2 = one low current (50mA) PGM output/input.
PC1575 (2-wire smoke option):
PGM1 = one low current (50mA) PGM output
PGM2 = one high current (300mA) PGM output/input
with 2-wire smoke detector capability
Please read Appendix D “PGM Output Options”
carefully for important information.
Powerful 1 Amp Regulated Power Supply:
550 mA Auxiliary Supply, 12 V
DC
Positive Temperature Coefficient (PTC) components
replace fuses
Supervision for loss of AC Power, Low Battery
Internal Clock Locked to AC Power Frequency
Power Requirements:
Transformer = 16.5 V
AC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed
lead acid
Remote Keypad Specifications:
Three Different Keypads Available:
- PC5506 six zone LED keypad
- LCD5500 Alphanumeric keypad
- PC1575RK six zone LED keypad
- SL-75 six zone LED keypad
The PC5506 and LCD5500 keypads have 5 Fully
Programmable Function Keys
Connect up to 8 Keypads
Four Wire (Quad) Connection to KEYBUS
Built in Piezoelectric Buzzer
SECTION1
Digital Communicator Specifications:
Supports Major Formats including SIA and Contact ID
Event Initiated Personal Paging
Three Programmable Phone Numbers
Two Account numbers
Supports LINKS 1000 Cellular Communication
DTMF and Pulse Dialing
DPDT Line Seizure
Anti-jam Feature
Split Reporting of Selected Transmissions to Each
Telephone Number
System Supervision Features:
The PC1575 continuously monitors a number of possible
trouble conditions including:
AC Power Failure
Trouble by Zone
Tamper by Zone
Fire Trouble
Telephone Line Trouble
Failure to Communicate
Low Battery Condition
Bell Output Trouble
Module Fault (Supervisory or Loss of Internal Clock
AUX Power Supply Fault Tamper)
False Alarm Prevention Features:
Audible Exit Delay
Audible Exit Fault
Communication Delay
Urgency on Entry Delay
Quick Exit
Additional Features:
Auto Arm at Specified Time
Keypad Activated Alarm Output and Communicator
Test
All modules connect to the system via a four wire
KEYBUS up to 1000’/300m from main panel
Event Buffer can be printed using PC5400 RS232 Serial
Interface module
Supports the ESCORT 5580 Voice Prompt Module with
Automation/Lighting Control
An Event Buffer which records the past 100 events with
both the time and date at which they occurred
Uploading and Downloading capability
• Local Downloading capability through the use of the
PC-LINK Adaptor
UL Installation
This equipment is UL Listed in accordance with UL1023
(Household Burglar Alarm System Units), UL985 (Household
Fire Warning System Units), UL1635 (Digital Alarm Annunciator
System Units), UL365 (Police Station Connected Burglar
Alarm Units and Systems), UL609 (Local Burglar Alarm Units
and Systems), UL1610 (Central Station Burglar Alarm Units).
This equipment has the capability of being programmed for
operational features that are not allowed for UL Listed Systems
or being connected to accessories not permitted.
Refer toRefer to
Refer toRefer to
Refer to
Appendix E for summary of requirements.Appendix E for summary of requirements.
Appendix E for summary of requirements.Appendix E for summary of requirements.
Appendix E for summary of requirements.