User Manual
Digital Security Controls Ltd. 60 Private and Confidential
Installation Manual DATE : 09/30/97 DRAFT
[405] ANSWERING MACHINE DOUBLE-CALL TIMER
Default
060 I__II__II__I (Valid entries are 001-255 seconds)
[406] NUMBER OF RINGS TO ANSWER ON
Default
000 I__II__II__I (Valid entries are 000-255 rings)
[499][Installer Code][499] INITIATE PCLINK
• ENTER [499] [INSTALLER CODE] [499]
INTERNATIONAL PROGRAMMING
[700] AUTOMATIC CLOCK ADJUST
Default
60 I___II___I (Valid entries are 00-99)
[701] FIRST INTERNATIONAL OPTIONS CODE
Default Option ON Option OFF
OFF I___I Option 1 50 Hz AC 60 Hz AC
OFF I___I Option 2 Time Base is Internal Crystal Time Base is AC Line
OFF I___I Option 3 AC/DC Arming Inhibit Enabled AC/DC Arming Inhibit Disabled
OFF I___I Option 4 All System Tampers Require Installer Reset All System Tampers follow Restore
OFF I___I Option 5 6-Digit User Access Codes 4-Digit User Access Codes
OFF I___I Option 6 Busy Tone Detection Enabled Busy Tone Detection Disabled
OFF I___I Option 7 High Current Battery Charge Standard Current Battery Charge
OFF I___I Option 8 For Future Use
[702] SECOND INTERNATIONAL OPTIONS CODE
Default Option ON Option OFF
OFF I___I Option 1 Pulse Dialing Make/Break Ratio is 33/67 Pulse Dialing Make/Break Ratio is 40/60
ON I___I Option 2 Force Dialing Enabled Force Dialing Disabled
OFF I___I Option 3 Land Line Test Tx Interval is in Minutes Land Line Test Tx Interval is in Days
OFF I___I Option 4 1600 Hz Handshake Standard Handshake
OFF I___I Option 5 ID Tone Enabled ID Tone Disabled
OFF I___I Option 6 2100 HZ ID Tone 1300 Hz ID Tone
OFF I___I Option 7 One Time 1-Hr User Enabled DLS Window Full 6-Hr User Enabled DLS Window
OFF I___I Option 8 Bell on FTC when armed FTC Trouble only when armed
[703] DELAY BETWEEN DIALING ATTEMPTS
Default
001 I___II___II___I (Valid entries are 000-255 seconds)
[801] NOT USED
[802] AUDIO INTERFACE
[10] Port Assignments, Zones 1-8
• Enter the nearest Intercom Port Number (01= Main Unit, 02= Remote Sounder, 00 = Not Used)