User Manual

Digital Security Controls Ltd. 58 Private and Confidential
Installation Manual DATE : 09/30/97 DRAFT
01 20 BPS, 1400 Hz handshake Note: 3
rd
Phone Number follows the
02 20 BPS, 2300 Hz handshake format of the 1
st
Phone Number
03 DTMF CONTACT I.D.
04 SIA FSK
05 Pager
Default
04 I___II___I 1st Phone Number
04 I___II___I 2nd Phone Number
[361] ALARM / RESTORE COMMUNICATOR CALL DIRECTIONS
Default Option ON Option OFF
ON I___I Option 1 1st Telephone Number Disabled
OFF I___I Option 2 2nd Telephone Number Disabled
OFF I___I Option 3-8 For Future Use
[363] TAMPER ALARM / RESTORE COMMUNICATOR CALL DIRECTIONS
Default Option ON Option OFF
ON I___I Option 1 1st Telephone Number Disabled
OFF I___I Option 2 2nd Telephone Number Disabled
OFF I___I Option 3-8 For Future Use
[365] OPENING / CLOSING COMMUNICATOR CALL DIRECTIONS
Default Option ON Option OFF
ON I___I Option 1 1st Telephone Number Disabled
OFF I___I Option 2 2nd Telephone Number Disabled
OFF I___I Option 3-8 For Future Use
[367] SYSTEM MAINTENANCE ALARM / RESTORE COMMUNICATOR CALL DIRECTIONS
Default Option ON Option OFF
ON I___I Option 1 1st Telephone Number Disabled
OFF I___I Option 2 2nd Telephone Number Disabled
OFF I___I Option 3-8 For Future Use
[368] SYSTEM TEST TRANSMISSIONS COMMUNICATOR CALL DIRECTIONS
Default Option ON Option OFF
ON I___I Option 1 1st Telephone Number Disabled
OFF I___I Option 2 2nd Telephone Number Disabled
OFF I___I Option 3-8 For Future Use
[370] COMMUNICATION VARIABLES
Default
003 I___II___II___I Swinger Shutdown (Alarms & Rest) (000-255 Transmissions, 000=disabled)
003 I___II___II___I Swinger Shutdown (Tampers & Rest) (000-255 Transmissions, 000=disabled)
003 I___II___II___I Swinger Shutdown (Maint & Rest) (000-255 Transmissions, 000=disabled)
000 I___II___II___I Communication Delay (000-255 seconds)
030 I___II___II___I AC Failure Communication Delay (000-255 minutes)
003 I___II___II___I TLM Trouble Delay (# of valid checks required +3= 003-255x10s)
030 I___II___II___I Test Transmission Cycle (land-line) (000-255 days)/(000-255 mins)
007 I___II___II___I Zone Low Battery Transmission Delay (000-255 days)
030 I___II___II___I Delinquency Transmission Delay (000-255 days/hours)
[371] TEST TRANSMISSION TIME OF DAY