User Manual

Digital Security Controls Ltd. 51 Private and Confidential
Installation Manual DATE : 09/30/97 DRAFT
[017] FIFTH SYSTEM OPTION CODE
Default Option ON Option OFF
OFF I___I Option 1 WLSKey Does Not Use Access Codes WLSKey Uses Access Codes
ON I___I Option 2 Verbal Chime is Enabled Verbal Chime is Disabled (Beeps only)
ON I___I Option 3 Verbal Alarm is Enabled Verbal Alarm is Disabled (Siren Only)
ON I___I Option 4 Local Annunciation Enabled Local Annunciation Disabled
xviii
OFF I___I Option 5 Remote Annunciation Enabled Remote Annunciation Disabled
OFF I___I Option 6 For Future Use
OFF I___I Option 7 For Future Use
OFF I___I Option 8 Squawk on Away Arming/Disarming Only Bell Squawk on all Arming/Disarming
ADVANCED SYSTEM PROGRAMMING
ZONE ATTRIBUTE DEFAULTS
Zone Type
On
Off
Opt. 1
Audible
Silent
Opt. 2
Steady
Pulsed
Opt. 3
Chime
No
Opt. 4
Bypass
No
Opt. 5
Force
No
Opt. 6
Swing.
No
Opt 7
Tx Del.
No
Opt. 8
Wireless
No
00 Null Zone Off Off Off Off Off Off Off On
01 Delay 1 On On On On Off On Off On
02 Delay 2 On On On On Off On Off On
03 Instant On On On On Off On Off On
04 Interior On On Off On Off On Off On
05 Interior, Stay-Away On On Off On On On Off On
06 Delay, Stay-Away On On Off On On On Off On
07-08 Not Used
xix
Off Off Off Off Off Off Off Off
09 24 Hour Supervisory Off On Off Off On Off Off On
10 24 Hr Superv. Buzzer Off On Off On Off Off Off On
11 24 Hour Burglary On On Off On Off Off Off On
12 24 Hour Holdup Off On Off Off Off Off Off On
13 24 Hour Gas On Off Off Off Off Off Off On
14 24 Hour Heat On Off Off Off Off Off Off On
15 24 Hour Medical On On Off Off Off Off Off On
16 24 Hour Panic On On Off Off Off Off Off On
17 24 Hour Emergency On On Off Off Off Off Off On
18 24 Hour Sprinkler On On Off Off Off Off Off On
19 24 Hour Water On On Off Off Off Off Off On
20 24 Hour Freeze On On Off Off Off Off Off On
21 24 Hour Latching Tamper On On Off Off Off Off Off On
22 Momentary Keyswitch Off Off Off Off On Off Off On
23 Maintained Keyswitch Off Off Off Off On Off Off On
24 Not Used Off Off Off Off Off Off Off On
25 Interior Delay On On Off On Off On Off On
87 Delayed 24Hr Fire (Wireless) On Off Off Off Off Off Off On
88 Standard 24Hr Fire (Wireless) On Off Off Off Off Off Off On