[008] MAINTENANCE CODE
Default
AAAA I___II___II___II___I
[012] KEYPAD LOCKOUT OPTIONS
Default
000 I___II___II___I Number of Invalid Codes Before Lockout (Valid entries are 000-255)
000 I___II___II___I Lockout Duration (in minutes) (Valid entries are 000-255)
[013] FIRST SYSTEM OPTION CODE
Default Option ON Option Off
OFF I___I Option 1 Hardwired Zones are NC Hardwired Zones are EOL
OFF I___I Option 2 Not Used
ON I___I Option 3 Not Used
OFF I___I Option 4 Tampers/Faults Do Not Sound as Open Tampers/Faults Sound as Open
OFF I___I Option 5 Not Used
ON I___I Option 6 Audible Exit Fault Enabled Audible Exit Fault Disabled
ON I___I Option 7 Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown
ON I___I Option 8 Temporal Three Fire Signal Enabled Standard Pulsed Fire Signal
[014] SECOND SYSTEM OPTION CODE
Default Option ON Option Off
OFF I___I Option 1 Arm/Disarm Bell Squawk Enabled Arm/Disarm Bell Squawk Disabled
OFF I___I Option 2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm
OFF I___I Option 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay
OFF I___I Option 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay
OFF I___I Option 5 Bell Squawk on Trouble No Bell Squawk on Trouble
ON I___I Option 6 Audible Exit With Urgency Silent Exit Delay
OFF I___I Option 7 Exit Delay Termination Enabled Exit Delay Termination Disabled
OFF I___I Option 8 Fire Bell is Continuous Fire Bell follows Bell Cut-off
[015] THIRD SYSTEM OPTION CODE
Default Option ON Option OFF
ON I___I Option 1 [F] Key Enabled [F] Key Disabled
OFF I___I Option 2 [P] Key Audible (Bell / Beeps) [P] Key Silent
OFF I___I Option 3 Quick Exit Enabled Quick Exit Disabled
ON I___I Option 4 Quick Arming Enabled (*0 and Function Keys) Quick Arming Disabled (Keys Req. Code)
OFF I___I Option 5 Code Required For Bypassing No Code Required
OFF I___I Option 6 Master Code Not Changeable Master Code Changeable
ON I___I Option 7 TLM Enabled TLM Disabled
OFF I___I Option 8 TLM Audible When Armed TLM Trouble Only When Armed
[016] FOURTH SYSTEM OPTION CODE
Default Option ON Option OFF
OFF I___I Option 1 Not Used
OFF I___I Option 2 Not Used
OFF I___I Option 3 Blank Unit When Not Used Unit Always Active
OFF I___I Option 4 Code Required to Remove Blanking No Code Required
ON I___I Option 5 Backlighting is Enabled Backlighting is Disabled
OFF I___I Option 6 Not Used
OFF I___I Option 7 Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed
OFF I___I Option 8 Not Used