[*][6][Master Code] ... When Disarmed
The [*][6] command is used to gain access to the following list of Master functions of the system.
[1] Time and Date Enter 4 digits for 24 Hour System Time
Enter 2 digits each for Month, Day and Year (HH-MM-MM-DD-YY)
Valid entries for the Hour are 00-23. Valid entries for the Minute are 00-59.
[2] Auto-Arm Control Pressing [2] while in the User Function menu will enable (3 beeps) or disable
(one long beep) the Auto-arm feature. With this feature enabled, the panel will
automatically arm in the Away mode (Stay Away zones active) at the same
time each day. The Auto Arm time is programmed with the [*][6][Master Code][3]
command.
NOTES: All arming inhibit features such as Latching Tampers, AC & DC inhibit, etc. shall
also inhibit the Auto Arm and send the Auto Arm Cancellation code.
Keypads are required if Auto-Arm is to be used.
[3] Auto-Arm Time The system can be programmed to arm at the same time . Upon entry of this
section, enter 4 digits for the 24 Hour Auto-Arm time.
At the selected Auto-Arm time, the WLS9000 will sound for 1 minute to warn
that an Auto-Arm is in progress. The siren can also be programmed to squawk once
every 10 seconds during this warning period. When the warning period is complete,
the system will arm with no exit delay and Stay Away zones active (if programmed).
Auto-Arming can be canceled only by entering a valid access code during
the 1-minute warning period. When the code has been entered, the warning will be
silenced and Auto-Arming will be canceled. Auto-Arming will be attempted at the
same time the next day. During the 1 minute warning period, keyswitch arming or
Quick arming will cancel the Auto-Arm process and will initiate the exit delay before
arming the system. Whenever the Auto-Arming process is canceled, the Auto Arm
Cancellation Reporting Code will be transmitted (if programmed).
If arming is inhibited by one of the following, the Auto Arm Cancellation
transmission will be communicated.
- AC / DC Inhibit Arm
- Latching System Tampers
- Zone Expander Supervisory Fault
[4] System Test The system’s Bell Output (2sec), Keypad Lights and Communicator are tested.
This test will also measure the panel’s standby battery.
[5] Enable DLS If enabled, this will open a window where rings will be detected by the panel. The
length and frequency of this window is dependant on the state of Option 7 in Section
[701].
[6] User Call-up If enabled by the Installer, when this command is executed, the panel will
make 1 attempt to call the downloading computer. The downloading computer must
be waiting for the panel to call before downloading can be performed.
[7] Volume Control The volume in which the ESCORT prompts can be controlled by entering this
section. Options are ‘Low’, ‘Medium’, ‘High’ and “Highest”, with Low as the default.
Note: Better control of the WLS9000’s volume can be achieved via the Volume
Function Key.
[8] Speech Rate The rate or speech can be changed upon entry of this section. Options are ‘fast’
and ‘slow’, with fast as the default.
[9] Not Used