User Manual

Digital Security Controls Ltd. 39 Private and Confidential
Installation Manual DATE : 09/30/97 DRAFT
This the minimum amount of tone required before the panel qualifies it as busy tone.
Valid entries are 004-255 (x25 milliseconds). Default is 026.
Note: Sections [704] to [709] will NOT be documented. Any changes required to these
parameters will be handled by ATE and/or Technical Support. All values programmed
[807] ESCORT Programming
[000] Function Key Programming
xiv
This section is used to program the Function Keys of the WLS9000. Upon entering this section, a 1 digit entry from
1 to 8 is required to select the function key to be programmed:
[0] Not Used
[1] Function Key 1 Assignment
[2] Function Key 2 Assignment
[3] Function Key 3 Assignment
[4] Function Key 4 Assignment
[5] Function Key 5 Assignment
[6] Function Key 6 Assignment
[7] Function Key 7 Assignment
[8] Function Key 8 Assignment
Upon selecting [1-8], a 2 digit entry is required to assign a function to the key (F1-F8)
After 2 digits are entered, the system will return to the previous section (in Section [000]).
Function Keys
Below are the options available for the Function Keys. If enabled, the function key must be held for 2 seconds in
order to perform the described function.
00 Null Key (Not Used)
The key is not used and will not perform any function when pressed.
01 Not Used
02 Not Used
03 Stay Arm
The system is Armed with all Stay/Away zones auto-bypassed regardless of whether or
not delay zones are tripped during the exit delay. This key only works while the system is
disarmed. The panel will log “Armed in Stay Mode” for this closing type.
04 Away Arm
The system is Armed with all Stay/Away zones active regardless of whether or
not delay zones are tripped during the exit delay. This key only works while the system
is disarmed. The panel will log “Armed in Away Mode” for this closing type.
05 [*][9] No-Entry Arm
After pressing this key, entry of a valid access code is required. Then the system will be Armed
with No Entry on Delay zones and all Stay/Away zones auto-bypassed regardless of whether or
not delay zones are tripped during the exit delay.
This key only works while the system is disarmed. Entry of a valid access is required
following this key to perform the function.
06 [*][4] Chime On / Off
This key Enables (3 beeps) and Disables (tone) just like pressing [*][4].
This key will work while the system is armed or disarmed.