User Manual
Digital Security Controls Ltd. 22 Private and Confidential
Installation Manual DATE : 09/30/97 DRAFT
[1] Bell Options
ON = An alarm causes the bell output to activate.
OFF = Silent Alarm.
[2] Bell Type
ON = The bell output will be steady when the zone is in alarm.
OFF = The bell output will pulse when the zone is in alarm.
[3] Chime Options
ON = The WLS9000 will chime both when the zone is violated and when the zone is
secured. Door Chime will work in both the armed and disarmed states.
OFF = The zone will not chime the keypads.
[4] Bypass Options
ON = The zone may be manually bypassed.
OFF = The zone cannot be bypassed.
[5] Force Arming Options
ON = The system may be armed with the zone violated. The zone will be temporarily
bypassed, and when the zone is secured it will be added back into the system.
OFF = The partition cannot be armed if this zone is open.
[6] Swinger Shutdown Options
ON = After the zone causes a programmed number of alarms, the zone will shut down so that no further
transmissions are sent to the monitoring station. The bell can follow Swinger Shutdown if
programmed.
OFF = Swinger Shutdown disabled
[7] Transmission Delay Options
ON = The reporting of zone alarms will be delayed for the programmed time. If a valid access code is
entered within this time, no alarm signal will be communicated.
OFF = When an alarm occurs, the reporting code is transmitted immediately.
[8] Wireless Option
ON = Zone is Wireless.
All Zones on the WLS9000 are wireless with the exception of the two Hardwired loops. Enabled is
the default condition of all Zone Definitions
OFF = Not Used
xiii
Note: Fire Zones attributes should not be changed. They should remain as defined by the
default settings.
[160] Maximum Dialing Attempts To Each Phone Number
This value represents the number of attempts that will be made to each telephone number when communicating.
The default value is 008 attempts. Valid entries are 001-015.
[161] Post Dial Wait For Handshake
This value represents the time the communicator waits for a valid initial handshake from the receiver after dialing
the programmed telephone number. The default value is 040 seconds.
[202]-[205] System Zone Assignments
These eight bit toggle section determines which zones on the system are enabled. All zones that are enabled will