User Manual
Digital Security Controls Ltd. 21 Private and Confidential
Installation Manual DATE : 09/30/97 DRAFT
This option is defaulted ON.
[3] Verbal Alarm Option
ON = Verbal Alarm is Enabled.
The WLS9000 will verbally annunciate audible zone alarms via their zone number (or programmed
label) in conjunction with the high volume piezo.
OFF = Verbal Alarm is Disabled.
The WLS9000 will only annunciate the high volume piezo during an audible alarm condition.
This option is defaulted ON.
[4]-[7] Not Used
[8] Bell Squawk on Away Arming Option
ON = Bell Squawk on Away Arming/Disarming Only
Bell Squawks will only be annunciated on Away Arming, as well as upon Disarming after being ared
in the Away Mode.
OFF = Bell Squawk on All Arming/Disarming
Bell Squawks will be annunciated on all types of Arming and Disarming (if programmed in Section
[014]).
This feature is defaulted OFF.
Notes: This feature is to prevent the Bell from being activated when arming from inside the premises.
This option follows the “Bell Squawk on Arming/Disarming” and “Bell Squawk Attribute” features.
8.2.6 Hardwired Zone Assignment [804] Subsections [71] and [72]
xi
This section determines which zone number corresponds to the Hardwired zones found on the main unit.
Enter the 2 digit zone number to be designated for each loop.
Please note that this section has moved to Sections [71] and [72] of the RF Slave (Section [804]).
Default
[71] Hardwired Zone Loop #1 Assignment 00 I___II___I (Valid entries are Zones 01-32)
[72] Hardwired Zone Loop #2 Assignment 00 I___II___I
8.2.7 Remote/Local Annunciation Options (Section [017] Options 4 and 5)
xii
New toggle options have been added in Section [017] has been added to the WLS9000 that allows the Installer to
have alarm/audio annunciation at the Local Unit, Remote Sounder, or both.
[4] Local Annunciation
ON = Annunciation Sounds Locally
All Audio and alarm annunciation is emitted from the main WLS9000 unit.
OFF = Annunciation Does Not Sound Locally
No alarm or audio annunciation is emitted from the main unit.
This Option is defaulted ON.
[5] Remote Annunciation
ON = Annunciation Sounds Remotely
All Audio and alarm annunciation is emitted from the Remote Sounder.
OFF = Annunciation Does Not Sound Remotely
No audio and alarm annunciation is emitted from the Remote Sounder.
This option is defaulted OFF.
8.2.8 Zone Attributes [101]-[132]
The following options can be enabled or disabled by zone.