User's Manual
Table Of Contents
- Table of Contents
- WARNING: Installer please read carefully
- General
- Model Information
- Panel Mounting
- Features
- Technical Specifications
- Ratings Compatibility
- Pre Installation Configuration
- Communicator Installation Configuration
- Installing Communicator in Panel
- Communicator Placement Test
- Initial Panel Programming
- SMS Command and Control
- Communicator Status LEDs
- Yellow Trouble LED
- Panel Supervision Trouble (2 Flashes)
- SIM Lock Trouble (4 Flashes)
- Cellular Trouble (5 Flashes)
- Ethernet Trouble (6 Flashes)
- Receiver Not Available (7 Flashes)
- Receiver Supervision Trouble (8 Flashes)
- FTC Trouble (9 Flashes)
- Module Configuration Trouble (12 Flashes)
- Red Network Connection Status LED
- (Green LED 1) (Green LED 2) and (Yellow LED) Signal Strength
- Network Activity LEDs - Red and Green(TL2803G(R)E / TL280LE(R) only)
- Communicator Troubleshooting
- Ethernet/Cellular Programming Options
- System Options
- Programming Options
- Communications Reporting Codes
- System Test Options
- Ethernet Receiver 1 Options
- Ethernet Receiver 2 Options
- Ethernet Options
- Cellular Receiver 1 Options
- Cellular Receiver 2 Options
- Cellular Options
- SMS Event Notification/Command and Control Options
- External Event Label Programming
- Receiver Diagnostic Testing
- System Information (Read Only)
- System Reset Defaults
- Ethernet Cellular Programming Worksheets
- System Options
- Programming Options
- System Test Options
- Ethernet Receiver 1 Options
- Ethernet Receiver 2 Options
- Ethernet Options
- Cellular Receiver 1 Options
- Cellular Receiver 2 Options
- Cellular Options
- Command and Control Options
- External Event Label Programming
- Receiver Diagnostic Testing
- System Information (Read Only)
- System Reset Defaults
- Limited Warranty
- EULA
- Regulatory Information
Default (ON)
[5] SMS Notification System Test Default (ON)
[6] SMS Notification Internal Events Default
(ON).
[7] SMS Notification Enabled Default (ON).
[8] SMS Command and Control Enabled
Default (ON).
[375]-[406] SMS Phone Number 1-32 Partition
Assignment
Default (00) Valid range: 00 - FF.
00 - Global; 01-32 - Partition; FF - Disabled
[420] Serial Port Baud Rate ('R' models only)
Default (05)
01=9600 Baud; 02=19200 Baud; 03=38400 Baud;
04=57600 Baud; 05=115200 Baud
[421] Serial Port Settings ('R' models only)
[1] Parity Enabled (OFF)
[2] Parity Type (OFF-Even Parity)
[3] 2 Stop Bit s (OFF-1 Stop Bit)
[4] Flow Control (OFF)
[422] Integration Identification Number
Default (MAC/IMEI)
[423] Session 1 Integration Access Code
Default (12345678) Valid range: 00000000 -
FFFFFFFF
[424] Session 1 SMS Label
Default (11111111)
_______________________________________
_______
[425] Session 1 Integration Toggle Options 2
[1] Integration Over Serial Port (ON)
[2] Integration Over Cellular (OFF)
[3] Integration Over Ethernet (OFF)
[4] Reserved
[5] Integration Protocol (ON)
[6] Interactive Protocol SMA (OFF)
[7] Reserved
[8] Interactive Encryption for SMA (ON)
[426] Session 1 Integration Toggle Options 3
[1] UDP Polling (OFF)
[2] TCP Polling (OFF)
[3] Real-time Notification (OFF)
[4] Notification Follows Pool (OFF)
[5] Reserved
[6] Reserved
[7] Reserved
[8] Reserved
[427] Session 1 Interactive Polling Interval
Default (000A) Valid range: 0000 - FFFF seconds.
[428] Session 1 Integration Server IP
Default (000.000.000.000)
[429] Session 1 Integration Notification Port
Default (0C00/00372) Valid range: 0000 - FFFF.
[430] Session 1 Integration Polling Port
Default (0C01/3073) Valid range: 0000 - FFFF.
[431] Session 1 Integration Server DNS
32 ASCII characters.
____________________________________
[432] Session 1 Integration Outgoing Port
Default (0C04/3076) Valid range: 0000 - FFFF.
[433] Session 1 Integration Incoming Port
Default (0BFF/3071) Valid range: 0000 - FFFF.
[434] Session 1 Notification Zone 1-8 Toggle
[1] Zone 1 Default (ON)
[2] Zone 2 Default (ON)
[3] Zone 3 Default (ON)
[4] Zone 4 Default (ON)
[5] Zone 5 Default (ON)
[6] Zone 6 Default (ON)
[7] Zone 7 Default (ON)
[8] Zone 8 Default (ON)
[435] Session 1 Notification Zone 9-16 Toggle
[1] Zone 9 Default (ON)
[2] Zone 10 Default (ON)
[3] Zone 11 Default (ON)
[4] Zone 12 Default (ON)
[5] Zone 13 Default (ON)
[6] Zone 14 Default (ON)
[7] Zone 15 Default (ON)
[8] Zone 16 Default (ON)
[436] Session 1 Notification Zone 17-24 Toggle
[1] Zone 17 Default (ON)
[2] Zone 18 Default (ON)
[3] Zone 19 Default (ON)
46