User's Manual
Table Of Contents
- Table of Contents
- WARNING: Installer please read carefully
- General
- Model Information
- Panel Mounting
- Features
- Technical Specifications
- Ratings Compatibility
- Pre Installation Configuration
- Communicator Installation Configuration
- Installing Communicator in Panel
- Communicator Placement Test
- Initial Panel Programming
- SMS Command and Control
- Communicator Status LEDs
- Yellow Trouble LED
- Panel Supervision Trouble (2 Flashes)
- SIM Lock Trouble (4 Flashes)
- Cellular Trouble (5 Flashes)
- Ethernet Trouble (6 Flashes)
- Receiver Not Available (7 Flashes)
- Receiver Supervision Trouble (8 Flashes)
- FTC Trouble (9 Flashes)
- Module Configuration Trouble (12 Flashes)
- Red Network Connection Status LED
- (Green LED 1) (Green LED 2) and (Yellow LED) Signal Strength
- Network Activity LEDs - Red and Green(TL2803G(R)E / TL280LE(R) only)
- Communicator Troubleshooting
- Ethernet/Cellular Programming Options
- System Options
- Programming Options
- Communications Reporting Codes
- System Test Options
- Ethernet Receiver 1 Options
- Ethernet Receiver 2 Options
- Ethernet Options
- Cellular Receiver 1 Options
- Cellular Receiver 2 Options
- Cellular Options
- SMS Event Notification/Command and Control Options
- External Event Label Programming
- Receiver Diagnostic Testing
- System Information (Read Only)
- System Reset Defaults
- Ethernet Cellular Programming Worksheets
- System Options
- Programming Options
- System Test Options
- Ethernet Receiver 1 Options
- Ethernet Receiver 2 Options
- Ethernet Options
- Cellular Receiver 1 Options
- Cellular Receiver 2 Options
- Cellular Options
- Command and Control Options
- External Event Label Programming
- Receiver Diagnostic Testing
- System Information (Read Only)
- System Reset Defaults
- Limited Warranty
- EULA
- Regulatory Information
[204] Cellular Receiver 1 Port
Default (0BF5/3061) Valid range: 0000 - FFFF.
[205] Cellular Receiver 1 APN
32 ASCII characters.
____________________________________
[206] Cellular Receiver 1 Domain Name
32 ASCII characters.
____________________________________
Cellular Receiver 2 Options
[211] Cellular Receiver 2 Account Code
Default (0000000000)
Valid range: 0000000001 - FFFFFFFFFE.
[212] Cellular Receiver 2 DNIS
Default (000000)
Valid range: 000000 - 0FFFFF.
[213] Cellular Receiver 2 Address
Default (000.000.000.000)
[214] Cellular Receiver 2 Port
Default (0BF5/3061) Valid range: 0000 - FFFF.
[215] Cellular Receiver 2 APN
Default ( ) 32 ASCII characters.
____________________________________
[216] Cellular Receiver 2 Domain Name
Default ( ) 32 ASCII characters.
____________________________________
Cellular Options
[221] Cellular Public Access Point Name
Default ( ) 32 ASCII characters
____________________________________
[222] Cellular Login User Name
Default ( ) 32 ASCII characters.
____________________________________
[223] Cellular Login Password
Default ( ) 32 ASCII characters.
____________________________________
[224] Cellular Test Transmission Time of Day
Default (9999) Valid range: 00 - 23 hrs. (HH) 00 -
59 min. (MM).
[225] Cellular Test Transmission Cycle
Default (000000)
Valid range: 000000 - 999999 minutes.
[226] Network Trouble Delay
Default (0F)
Valid entries from, 00 to FF.
[227] Voice Call Timeout
Default (00)
Valid entries from, 00 to FF.
[228] Voice Call Back Time
Default (0A)
Valid entries from, 00 to FF.
[229] Voice Call Back Number
________________________________
Command and Control Options
[301] Command and Control Toggle Options
[1] SMS Notification (ON).
[2] Serial Communication Port enabled (OFF)
[3] SMS Command and Control Default (ON).
[4] Interactive (OFF)
[5] SMS Character Format (OFF)
[6] Long SMS Message Handling Default
(OFF).
[7] Reserved
[8] Reserved
[307] SMSDelimiter
Default ()
Valid entries from, 00 to FF.
[308] Outgoing SMS Retry Attempts
Default (19)
Valid entries from, 00 to FF.
[309] Outgoing SMS Retry Counter
Default (000F) Valid range: 0000 - FFFF.
[311]-[342] SMS Phone Number 1-32
_______________________________________
_______
[343]-[374] SMS Phone Number 1-32 Toggle
Options
[1] SMS Notification Alarm/Restore Default
(ON).
[2] SMS Notification Tamper/Restore Default
(ON)
[3] SMS Notification Opening/Closing Default
(ON)
[4] SMS Notification System Maintenance
45