User's Manual
Table Of Contents
- WARNING: Installer please read carefully
- General Information
- Communicator Technical Specifications
- Communicator Pre Intsallation Configuration
- Communicator Configuration with SCW
- Installation Location
- Installing CAT 5 Cable (TL2553G(R)-E only)
- INSERTING/REMOVING THE SIM CARD
- Communicator Reset
- Establishing a Communication Channel with the SCW Panel.
- Initial Programming of Communicator and SCW
- SMS Command and Control Functions
- Label Programming for SMS Message
- Communicator Placement Test
- Ethernet/Cellular Programming Options
- System Options
- Programming Options
- Communications Reporting Codes
- System Test Options [026 - 029]
- Ethernet Receiver 1 Options
- Ethernet Receiver 2 Options
- Ethernet Options
- Cellular Receiver 1 Options
- Cellular Receiver 2 Options
- Cellular Options
- Command and Control Options
- SMS Command and Control Functions
- SMS Command and Control Response
- Receiver Diagnostic Testing
- System Information (Read Only)
- System Reset Defaults
- Communicator Troubleshooting
- Communicator Troubleshooting
- Ethernet Cellular Programming Worksheets
- EULA
- Limited Warranty
- Regulatory Information
Table 12: Ethernet Test Transmission Interval
Test Transmission Interval Daily Weekly Monthly
Programmed Minutes 001440 010080 043200
NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes will disable test transmission.
Cellular Receiver 1 Options
[201] Cellular Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account code is used when trans-
mitting heartbeat signals to the central station receiver. Signals received from the control panel will use the control panel
account number. Valid range: 0000000001 - FFFFFFFFFE. Programming all 0 or all F will cause a Module Configuration
Trouble (yellow LED = 12 flashes).
[202] Cellular Receiver 1 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the Communicator module at the central station. Valid range:
000000 - 099999. Values are entered as leading 0 followed by the five digit DNIS. Format is BCD.
NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS.
[203] Cellular Receiver 1 Address
Default (000.000.000.000)
Enter the Cellular Receiver 1 IP address. This information will be provided by your central station system administrator. Each 3-
digit segment of the address must be within a valid range of 000-255.
NOTE: When a valid IP address has been entered, the Cellular is enabled and will communicate events over the Cellular chan-
nel.
[204] Cellular Receiver 1 Port
Default (0BF5/3061)
This Section determines the port used by Cellular Receiver 1. Change the default value of this port when your installation is loc-
ated behind a firewall, and must be assigned a particular port number as determined by your central station system admin-
istrator. Valid range: 0000 - FFFF.
NOTE: Programming this Section with 0000 will disable the receiver.
[205] Cellular Receiver 1 APN
Default ( )
The Access Point Name (APN) determines the Cellular network that the Communicator will connect to. This information is avail-
able from your network carrier. Program this Section as 32 ASCII characters.
NOTE: When a SIM card with a custom APN is used, the unit will not have access to the Internet.DLS and remote flash can still
be done if Section [221] is programmed with a valid Public APN.
[206] Cellular Receiver 1 Domain Name
Default ( )
Programming this Section is not permitted on a UL/ULC listed system.
Enter the Domain Name as 32 ASCII characters. This information will be provided by your central station system administrator.
Cellular Receiver 2 Options
[211] Cellular Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between different transmitters. This account code is used when
transmitting signals to the central station receiver. Signals received on the panel will use the panel account number. Valid
range: 0000000001 - FFFFFFFFFE.
NOTE: Programming this Section as all 0 or F will cause a Module Configuration Trouble (yellow LED = 12 flashes).
[212] Cellular Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the Account Code to identify the Communicator module at the central station. Valid range:
000000 - 099999. Values are entered as a 0 followed by the 5 digit DNIS value. Format is BCD.
NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS.
[213] Cellular Receiver 2 Address
Default (000.000.000.000)
Enter the Cellular Receiver 2 IP address. This IP address will be provided by your central station. Format is 4 fields, each field is
3-digit decimal. Valid range: 000 - 255.