User's Manual
Table Of Contents
- WARNING: Installer please read carefully
- General Information
- Communicator Technical Specifications
- Communicator Pre Intsallation Configuration
- Communicator Configuration with SCW
- Installation Location
- Installing CAT 5 Cable (TL2553G(R)-E only)
- INSERTING/REMOVING THE SIM CARD
- Communicator Reset
- Establishing a Communication Channel with the SCW Panel.
- Initial Programming of Communicator and SCW
- SMS Command and Control Functions
- Label Programming for SMS Message
- Communicator Placement Test
- Ethernet/Cellular Programming Options
- System Options
- Programming Options
- Communications Reporting Codes
- System Test Options [026 - 029]
- Ethernet Receiver 1 Options
- Ethernet Receiver 2 Options
- Ethernet Options
- Cellular Receiver 1 Options
- Cellular Receiver 2 Options
- Cellular Options
- Command and Control Options
- SMS Command and Control Functions
- SMS Command and Control Response
- Receiver Diagnostic Testing
- System Information (Read Only)
- System Reset Defaults
- Communicator Troubleshooting
- Communicator Troubleshooting
- Ethernet Cellular Programming Worksheets
- EULA
- Limited Warranty
- Regulatory Information
Program 00 to disable this event transmission or FF to enable. This event will occur when the panel firmware update begins.
[036] Panel Firmware Update Successful
Default (FF);
Program 00 to disable this event transmission or FF to enable. This event will occur when the panel firmware is updated suc-
cessfully.
[037] Panel Firmware Update Fail
Default (FF);
Program 00 to disable this event transmission or FF to enable. This event will occur when the panel firmware updated has
failed.
Table 11: Panel Tamper Alarm Restore
Event
SIA
Identifier
SIA
Reporting
Code
Contact ID
Qualifier
Contact ID
Event Code
Contact ID
Reporting
Code
Contact ID
User/Zone
[033]Comm. FW Update Begin LB 00 1 9 03 002
[034]Comm. FW Update Successful LS 00 3 9 03 002
[035]Panel FW Update Begin LB 00 1 9 03 003
[036]Panel FW Update Successful LS 00 3 9 03 003
[037]Panel FW Update Fail LU 00 1 9 04 003
Ethernet Receiver 1 Options
[101] Ethernet Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account code is used when trans-
mitting heartbeat signals to the central station receiver. Signals received from the Panel will use the control panel account num-
ber. Valid range: 0000000001-FFFFFFFFFE. Programming all 0 or all F will cause a Module Configuration Trouble.
NOTE: If Ethernet Receiver 1 and Cellular Receiver 1 are programmed as the same receiver (IP and port number are
identical), Ethernet Receiver 1 account code will be used.
[102] Ethernet Receiver 1 DNIS
Default (000000)
The Dialled Number Information Service (DNIS) is used in addition to the Account Code to identify the Communicator module
at the central station. Valid range: 000000 - 099999. Value is entered as a leading 0 followed by the 5 digit DNIS. Format is Bin-
ary Coded Decimal (BCD).
NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS.
[103] Ethernet Receiver 1 Address
Default (127.000.000.001)
The default address enables the Communicator to operate in Unattended Mode.
Unattended Mode is used when a receiver is not available and the unit is required to perform DLS sessions. Typically used
where the customer programs the control panel daily due to access control and still wants to receive alarms without buying
extra hardware (receiver) or software.
NOTE: When a valid IP address has been programmed, Ethernet Receiver 1 is enabled and will communicate events over the
Ethernet channel.
Ethernet Receiver 1 and Cellular Receiver 1 may be configured to communicate to the same central station receiver. To con-
figure the device to operate using this Common Receiver Mode functionality, program Ethernet Receiver 1 and Cellular
Receiver 1, IP address and port number with identical values.
NOTE: When operating in Common Receiver Mode, Ethernet Receiver 1 account code will be used for Ethernet and Cellular.
[104] Ethernet Receiver 1 Remote Port
Default (0BF5/3061)
This Section determines the remote port of Ethernet receiver 1. Valid range: 0000 - FFFF.
[105] Ethernet Receiver 1 Local Port
Default (0BF4/3060)
Use this Section to set the value of the local outgoing port. Set the value of this port when your installation is located behind a
firewall and must be assigned a particular port number as determined by your central station
system administrator. Valid range: 0000 - FFFF.
[106] Ethernet Receiver 1 Domain Name
Default ( )
18