User's Manual
Table Of Contents
- WARNING: Installer please read carefully
- General Information
- Communicator Technical Specifications
- Communicator Pre Intsallation Configuration
- Communicator Configuration with SCW
- Installation Location
- Installing CAT 5 Cable (TL2553G(R)-E only)
- INSERTING/REMOVING THE SIM CARD
- Communicator Reset
- Establishing a Communication Channel with the SCW Panel.
- Initial Programming of Communicator and SCW
- SMS Command and Control Functions
- Label Programming for SMS Message
- Communicator Placement Test
- Ethernet/Cellular Programming Options
- System Options
- Programming Options
- Communications Reporting Codes
- System Test Options [026 - 029]
- Ethernet Receiver 1 Options
- Ethernet Receiver 2 Options
- Ethernet Options
- Cellular Receiver 1 Options
- Cellular Receiver 2 Options
- Cellular Options
- Command and Control Options
- SMS Command and Control Functions
- SMS Command and Control Response
- Receiver Diagnostic Testing
- System Information (Read Only)
- System Reset Defaults
- Communicator Troubleshooting
- Communicator Troubleshooting
- Ethernet Cellular Programming Worksheets
- EULA
- Limited Warranty
- Regulatory Information
Program 00 to disable this event or FF to enable. This event will occur when communications with the control panel have
resumed.
[025] Radio Activation Restore
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur after any successful Connect24 programming session.
System Test Options [026 - 029]
Test Transmissions to Primary Receiver, with Backup to Secondary Receiver:
Set Ethernet Section [026] to (FF); [027] to (00). Set Cellular Section [028] to (FF); [029] to (00).
l If the test transmission fails to the primary receiver it will backup to the secondary receiver.
l If the test transmission fails to the secondary receiver an FTC trouble will be generated.
Test Transmission Unique to Primary and Secondary Receivers:
Set Ethernet Section [026] to (FF); [027] to (FF). Set Cellular Section [028] to (FF); [029] to (FF).
l The module will send periodic test transmissions to each receiver independently, with no backups.
l If the test transmission fails to any of the programmed receivers, an FTC trouble will be generated.
Alternate Test Transmission:
Alternate Test Transmission can be enabled or disabled in Section [005] Toggle Option [7].
[026] Ethernet 1 Transmission
Default (FF)
Program 00 to disable this event transmission or FF to enable. See System TestOptions (above) for details on settings.
[027] Ethernet 2 Transmission
Default (00)
Program 00 to disable this event transmission or FF to enable. See System TestOptions (above) for details on settings.
[028] Cellular 1 Transmission
Default (FF)
Program 00 to disable this event transmission or FF to enable. See System TestOptions (above) for details on settings.
[029] Cellular 2 Transmission
Default (00)
Program 00 to disable this event transmission or FF to enable. See System TestOptions (above) for details on settings.
NOTE: The time interval (in minutes) between periodic tests is programmed in Section [125] (Ethernet) and Section [225] (Cel-
lular).
[030] FTC Restore
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when an FTC Trouble on the system
restores.
[031] Priority Tamper Alarm
Program 00 to disable this event or FF to enable. This event will occur when panel tampered during the entry delay.
[032] Priority Tamper Restore
Program 00 to disable this event or FF to enable.This event will occur when panel tamper restored.
Table 10: Priority Temper Restore
Event
SIA
Identifier
SIA Reporting
Code
Contact ID
Qualifier
Contact ID
Event Code
Contact ID
Reporting Code
Contact ID
User/Zone
PriorityTamper BA 000 1 1 37 000
PriorityTamper Restore BR 000 3 1 37 000
[033] Communicator Firmware Update Begin
Default (FF);
Program 00 to disable this event transmission or FF to enable. This event will occur when the communicator firmware update
begins.
[034] Communicator Firmware Update Successful
Default (FF);
Program 00 to disable this event transmission or FF to enable. This event will occur when the communicator firmware update
successfully completed.
[035] Panel Firmware Update Begin
Default (FF);
17