User's Manual

Keypad Function Keys
Please see your system installation manual for more details on the function key
options below.
Keypad Programming
Enter keypad programming by entering Installer Programming, then Section [861] to
[876], which apply to keypads 1-16.
[860] Keypad Slot Number
This is not for programming; the two-digit slot number is displayed for information
only.
[861]-[876] Keypad Programming Sections
[000] Address of Partition
Upon selecting [000], a 2-digit entry is required to assign the keypad to a partition.
Entering 00 assigns the keypad as global. Valid entries are 00-32. The default is 01.
[001]-[005] Function Key 1-5 Assignment
[011] Keypad Input/Output Programming
[012] Local PGM Output Pulse Activation Time
[021] First Keypad Options
[022] Second Keypad Options
[00] - Null [16] - Quick Exit [37]-[50] For Future Use
[01] - Disarm [17] - Arm Interior [51]- [A] Key Alarm
[02] - Instant Stay
Arm
[18]-[20] - For Future Use [52] - [P] Key Alarm
[03] - Stay Arm [21] - Command Output 1 [53] - [92] For Future Use
[04] - Away Arm [22] - Command Output 2
[05] - [*][9] No-Entry
Arm
[23] - Command Output 3
[06] - Chime ON/
OFF
[24] - Command Output 4
[07] - System Test [25]-[28] - For Future Use
[08] - For Future Use
[29] - Bypass Group
Recall
[09] - Night Arm [30] - Quick Bypass
[10] - For Future
Use
[31] - For Future Use
[11] - Away Arm no
Entry
[32] - For Future Use
[12] - Global Stay
Arm
[33] - Bypass Recall
[13] - Global Away
Arm
[34] - For Future Use
[14] - Global Dis-
arming
[35] - For Future Use
[15] - For Future Use
[36] - Reactivate Stay/
Away and Night Zones
Default
Zone or PGM
Number 00 I_____I_____I_____I
I_____I_____I
Minutes (00-99)
I_____I_____I
Seconds (00-99)
Default Opt. ON OFF
ON I_____I 1
Fire Key Enabled Fire Key Disabled
ON I_____I 2
Medical Key Enabled Medical Key Disabled
ON I_____I 3
Panic Key Enabled Panic Key Disabled
ON I_____I 4
Display Access Code
When Programming
Display X’s When Pro-
gramming Access
Codes
OFF I_____I 5
For Future Use For Future Use
OFF I_____I 6
For Future Use For Future Use
OFF I_____I 7
For Future Use For Future Use
OFF I_____I 8
For Future Use For Future Use
Default Opt. ON OFF
ON I_____I 1
Local Clock Display ON
Local Clock Display
OFF
OFF I_____I 2
Local Clock Displays 24-hr
Time
Local Clock Displays
AM/PM
ON I_____I 3
Auto Alarm Scroll ON Auto Alarm Scroll OFF
OFF I_____I 4
For Future Use For Future Use
OFF I_____I 5
Power LED Enabled Power LED Disabled