User's Manual

5
1 Quick Reference
The HS Series Alarm System uses a menu based navigation system. The scroll keys are used to
cycle through the list of actions contained within the current menu. However, many actions can also be
accessed using a shortcut key. If an action can be accessed using a shortcut key, the key will be listed in the
instructions below. If you see [Scroll] use the keys to cycle to the listed menu item. Lookup
detailed information on any of the listed actions using the accompanying Section number.
NOTE: Some features must be enabled by installer.
Status Lights
Ready - Indicates system normal. Must be on to arm system. All zones must be secured or bypassed and the system
disarmed for this light to activate.
Armed- Indicates system is armed. If the Ready light and the Armed light are both on it indicates an Exit Delay is in
progress.
Trouble - On indicates a system malfunction or tamper. Flashing indicates that the keypad has a low battery
condition. Follow the instructions displayed or enter [*][2] to view trouble. Correcting the trouble turns of the
indicator.
AC Power - Indicates AC Power is present. The AC Power light will turn off when AC is absent.
Action Press Section
Arming and Disarming
Away Arm
for 2 seconds
4.1.1
Stay Arm
for 2 seconds
4.1.2
Night Arm
+ [Access Code]
4.1.3
Disarm [Access Code] 4.4
No-Entry Arming
+ [Access Code]
4.1.4
Quick Arm/Quick Exit 4.1.1
Bypass Zone
+ [Access Code] + [3 Digit Zone #] +
4.5
Bypassing
Recall Last Bypass
+ [Access Code] + [Scroll] Bypass Options +
4.5
Clear Bypass
+ [Access Code] + [Scroll] Bypass Options + + [Scroll]
Clear Bypasses +
4.5
Load Bypass Group
+ [Access Code] + [Scroll] Bypass Options + + [Scroll]
Bypass Group +
4.5.1
Common Functions
Select Language
for 2 seconds
8.1
Set Time and Date
[Master Code] +
8.3.2
Turn Chime ON/OFF 8.2
Change Brightness
[Master Code] +
8.3.8
Change Contrast
[Master Code] +
8.3.9
Add/delete user
+ [Access Code] + [Scroll] Access Code +
7.1.1
Reset Sensors 5.4
View Troubles 9.1
View Alarms 5.5
Perform System Test
[Master Code] +
11.1
Buzzer Volume
[Master Code] +
8.3.10
*
*
*
9
*