User's Manual
4 Securing the Premises
11
4.1.4 No-Entry Arming
No-Entry Arming arms the system in Stay mode by:
• Removing the Entry Delay from all configured zones.
• Arming all perimeter sensors.
• Bypassing all interior sensors.
An entry through any zone will create an instant alarm.
To Arm the System in Night mode What you see
1. Once the system is armed in Stay mode (Armed indicator is on) at any key-
pad press
OR
press .
Date Time
JAN 02/13 2:06a
then
Press (*) for <>
Interior Arm
2. If required enter your [access code]. All interior zones will now be armed
except for devices programmed as Night Zones.
The Night mode icon turns on.
Enter Your
Access Code
then
Interior Has
Been Armed
To gain access to interior areas that are armed during Night mode
• Disarm the system by entering your [access code].
To No-Entry Arm the System What you see
1. Check that the Ready indicator is on and your system is ready to be armed.
Date Time
JAN 02/13 2:06a
2. Press and enter your [access code].
Enter Your
Access Code
3. If zones have been bypassed a warning appears.
* Warning *
Bypass Active
then
4. After successfully initiating the arming sequence the:
• Armed light flashes as a reminder that the system is armed and has no
entry delay.
• Keypad sounds fast beeps.
• Keypad displays “Exit Delay in Progress”.
Armed With No
Entry Delay
then
Exit Delay in
Progress
5. To cancel the arming sequence, enter your [access code].
System Disarmed
No Alarm Memory
6. Once the exit delay timer expires the system is armed.
System Armed
in Stay Mode
*
*
*
1
*
9