User's Manual
4 Securing the Premises
10
4.1.2 Stay Arming the System with the Keypad
Stay mode partially activates your alarm system by:
• Arming all perimeter sensors.
• Bypassing all interior sensors.
4.1.2.1 Silent Exit Delay
If the system is armed using the Stay key or the No Entry Arming method :
• The warning beep is silenced.
• The exit time is doubled for that exit period only (CP-01 versions only).
4.1.3 Night Arming the System with the Keypad
Night mode partially activates the alarm system by:
• Bypassing all internal sensors configured as Night zones.
• Arming all perimeter sensors.
• Arming all other internal sensors.
Arming the system in Night mode is only possible after the system has first been armed in Stay mode. To
access armed interior areas when the system is armed in Night Mode you must disarm the system.
To Arm the System in Stay mode What you see
1. Ensure all windows and doors are closed and that the Ready indicator is on.
Date Time
JAN 02/13 2:06a
2. Press and hold the Stay key for 2 seconds and if required enter your
[access code]. Do not leave the premises.
System is
Ready to Arm
then
Enter Your
Access Code
3. If zones have been bypassed a warning appears.
* Warning *
Bypass Active
4. After successfully initiating the arming sequence the:
• Armed indicator turns on.
• Ready indicator remains lit.
• Exit Delay timer begins counting down.
Exit Delay in
Progress
5. To cancel the arming sequence, enter your [access code].
System Disarmed
No Alarm Memory
6. Once the exit delay timer expires thereby arming the system the:
• Ready indicator turns off.
• Armed indicator remains on.
• Bypass or system indicator activates.
System Armed
in Stay Mode
NOTE: For non CP-01 versions, Standard Exit Time is used.
NOTE: Ensure that your installer has provided you with a list identifying all programmed night zones.
*
9
DRAFT 3