User's Manual
9
Two test results are provided:
• 24-hour: Average signal status results received during a 24-hour period.
• Now: Signal status results of the current test.
The following status indicators may be displayed:
Table 2-10 Wireless Device Status Indications
[610] Show All Devices
The results of [600] Test all devices are displayed in this section. This section is only
available if a test has been completed.
[611] Show RF Problems
Similar to section [610] Show All Devices, except that only problematic test results are
displayed (i.e., Poor, 1-way, Not Test, Early).
2.5.8 [521]-[552] Programming Wireless Keys
To program wireless key buttons:
1. Enter Installer Programming section [804] (Wireless Programming)>[521]-[552]
(Wireless Key Buttons).
2. Select a wireless key to program (001-032) using the scroll keys or by entering a hot-
key.
3. Select one of the following options by scrolling or entering the hotkey:
Table 2-11 Wireless Key Button Programming Options
602 Test wireless keys Test individual wireless keys. Once in this section,
press a button on the wireless key to begin the test.
603 Test sirens Test each enrolled wireless siren.
604 Test repeaters Test each enrolled wireless repeater.
Strong Strong signal strength
Good Good signal strength
Poor Poor signal strength
1-Way The device is operating in 1-way mode only. The
alarm panel cannot configure or control the device
Not Test Displayed as the Now result if no test was per-
formed.
None Always displayed as the 24-hour result when testing
wireless keys.
Early Displayed as the 24-hour result when the panel has
been powered up for less than 24 hours.
00 Disabled 14 Global Disarm 34 User Programming
01 Stay Arm 17 Comm. Output 1 35 User Functions
02 Away Arm 18 Comm. Output 2 36 Reactivate Stay/
Away/Night
03 [*][9] No Entry 19 Comm. Output 3 37 Time/Date Prog.
04 Instant Stay Arm 20 Comm. Output 4 39 Trouble Display
05 Night Arm 27 Bypass Mode 40 Alarm Memory
07 Disarm 28 Bypass Recall 98 Aux. Alarm
09 Quick Exit 29 Bypass Group
Recall
99 Panic
11 Away No Entry 30 Quick Bypass
12 Global Stay Arm 32 Chime On/Off