User's Manual

16
[804][081] Wireless Supervisory Window (Default = 96)
The window is programmed in 15 minute increments.
The default programming is:
96 (x15minutes), which is equal to 24 hours (NA), or
8 (x15minutes), which is equal to 2 hours (EU).
Valid entries are (004) to (096), equal to 1 to 24 hours.
[804][082]-[089] Zone Transmitter Supervision
[082] Zone 1-8 [083] Zones
9-16
[084] Zones
17-24
[085] Zones
25-32
Opt Def. Def. Def. Def.
1 Zone 1 Zone 9 Zone 17 Zone 25
2 Zone 2 Zone 10 Zone 18 Zone 26
3 Zone 3 Zone 11 Zone 19 Zone 27
4 Zone 4 Zone 12 Zone 20 Zone 28
5 Zone 5 Zone 13 Zone 21 Zone 29
6 Zone 6 Zone 14 Zone 22 Zone 30
7 Zone 7 Zone 15 Zone 23 Zone 31
8 Zone 8 Zone 16 Zone 24 Zone 32
[086] Zone
33-40
[087] Zones
41-48
[088] Zones
49-56
[089] Zones
57-64
Opt Def. Def. Def. Def.
1 Zone 33 Zone 41 Zone 49 Zone 57
2 Zone 34 Zone 42 Zone 50 Zone 58
3 Zone 35 Zone 43 Zone 51 Zone 59
4 Zone 36 Zone 44 Zone 52 Zone 60
5 Zone 37 Zone 45 Zone 53 Zone 61
6 Zone 38 Zone 46 Zone 54 Zone 62
7 Zone 39 Zone 47 Zone 55 Zone 63
8 Zone 40 Zone 48 Zone 56 Zone 64
Options
   
   
   
   

  
   
   
   
   
   
   
   
   
   
   
   