User's Manual

2G Alarm Communicator Installlation Manual SMS Command and Control Response
29
Enter the Domain Name as 32 ASCII characters. This information will be provided by your central station system administrator.
[698] Interactive over 2G local event report port (UDP Port)
Default (3076)
This Section is used to program the DUP port number used the communicator.
[699] Interactive over 2G local control response port (TCP Port)
Default (3071)
This Section is used to program the TCP port number used by the communicator.
[701] Interactive Over 2G Server 2 account code
Default (0000000000)
The account code is used by interactive server to distinguish between different transmitters.
[702] Interactive Over 2G Server 2 DNIS
Default (0000000000)
The DNIS is used in addition to the account to identify the communicator module at the interactive server.
[703] Interactive Over 2G server 2 IP address
Default (000.000.000.000)
Enter the interactive over data server 2 IP address. This information will be provided by your interactive server administrator. Each 3
digit segment of the address must be within the valid range of 000-255.
NOTE: When a valid IP address has been entered, the interactive server is enabled and will communicate events over the data channel.
[704] Interactive Over 2G Server 2 TCP port
Default ( )
This Section determines the TCP port used by interactive server 1 for control response. Change the default value of this port when your
installation is located behind a firewall, and must be assigned a particular port number as determined by your central station system
administrator.
Valid range: 0000 - FFFF
[705] Interactive over 2G server 2 UDP port
Default ( )
This Section determines the UDP port used by interactive server 1 t events communication. Change the default value of this port when
your installation is located behind a firewall, and must be assigned a particular port number as determined by your central station sys-
tem administrator.
Valid range: 0000 - FFFF
[706] Interactive over 2G server 2 APN
Default ( )
The Access Point Name (APN) determines the interactive server network that the Communicator will connect to. This information is
available from your network carrier. Program this Section as 32 ASCII characters.
NOTE: The Server 1 APN should be same as the receiver 1 APN in section [215]
[707] Interactive Over data Server 2 Domain name
Default ( )
Enter the Domain Name as 32 ASCII characters. This information will be provided by your central station system administrator.
[708] Event report retry interval
Default (0102040810101010)
This section is used to program the event transmission to interactive server retry time interval. The interval time given in seconds.
(The default reties are after 1 second, 2 second, 4 second, 8 second and 10 seconds x4)
[709] Event report retries timeout
Default (300)
This section is used to program the time to try communicating the event before giving up the event transmission. The time is given in
seconds.
[710] Event buffer upload timeout
Default (86400)
This section is used to program the time before discarding the event buffer content. The time is given in seconds.
[711] TCP connection time out
Default (1200)
This section is used to program the time to keep the TCP connection open for control response.
29008218R001_NOVA_TL255GS_GS2055_V.2.5X_IM_ENG_NA_UL_ULC_FCC_IC_dft_03