User's Manual
2G Alarm Communicator Installlation Manual SMS Command and Control Response
25
[626] System Night Armed
Default (Night Armed);
This label will be included in the response to a status request command if a partition is night armed.
[627] System Disarmed Ready
Default (Disarmed Ready);
This label will be included in the response to a status request command if a partition is disarmed and is ready to arm.
[628] System Disarmed Not Ready
Default (Disarmed Not Ready);
This label will be included in the response to a status request command if a partition is disarmed and is not ready to arm.
[629] System is in Alarm
Default (is in Alarm);
This label will be included in the response to a status request command if a partition is in alarm.
[630] Trouble Label
Default (Service is Required);
This label will be included in the response to the Alarm Memory command if there are no alarms in memory.
[631] No Alarms in Memory
Default (No Alarm Memory);
This label will be included in the response to an Alarm Memory Request if there are no alarms on the system.
[634] Error Code
Default (Error Code);
When an SMS initiated function fails, the module will send an error code to the telephone number that was source of the
SMS request. Message format is: [Account Label] [Date and Time] [Error Code] [Error Type]. Fields are “space” delimited.
Interactive Options
(TL255GS and GS2055 only)
[651] Interactive Account Code
Default (MAC or IMEI);
This section is programmed as 2 field by 6 hexadecimal number (12 characters). Valid range for each field is
000000 ~ FFFFFF. The IMEI can be viewed in Section [997]. The MAC address can be viewed in Section [998].
[652] Interactive Access Code
Default (12345678);
This section is programmed with the hexadecimal Interactive access code. Valid range is 0000 ~ FFFF.
[662] Interactive Port Settings Toggle
Program this section Toggles to select the Parity used for Interactive data transfers:
[1] Parity Enable05
Default (OFF)
ON: Parity is enabled.
OFF: Parity is disabled.
[2] Parity Type
Default (OFF)
ON: Even Parity is enabled.
OFF: Odd Parity is enabled.
[3] Stop Bits
Default (OFF)
ON: One Stop bit is used.
OFF: Two Stop bits are used.
[4] Flow Control
Default (OFF)
ON: Flow Control is enabled.
Table 17: Error Code Format
Class Definition Error Definition
01 DLS
01 Bad SMS format
02 Session failed due to local network issues
03 Unable to connect to remote server
04 Bad DLS access code
05 DLS lockout active
02 TFTP
01 Bad SMS format
02 Session failed due to local network issues
03 Unable to connect to remote server
04 File not found on TFTP server
29008218R001_NOVA_TL255GS_GS2055_V.2.5X_IM_ENG_NA_UL_ULC_FCC_IC_dft_03