ZONE LABEL PROGRAMMING
[401] - [464] Zone 1 - 64 Label
Default (Zone n);
Where n is a Zone number from 1 - 64. Zone Labels are up to 32 ASCII characters. Labels are used to identify the Zone for notification
messages that apply to a specific Zone. The label language is specified in Section [009]. Zone labels are numbered 1 - 64 and Zones are
numbered 1-128. No labels are assigned to Zones 65-128.
PANEL EVENT LABEL PROGRAMMING
[501] - [580] Event Labels
Default (see Default Label in Table 15 );
There are 80 programmable Event labels. Each label is pre programmed with the default text shown in Table 15 .
Each label is up to 32 ASCII characters (including spaces). The language is specified in Section [009].
Table 15: Panel Event Labels
Event [Section] Label Default Label Event [Section] Label Default Label
[501] Burglary Alarm [Burglary Alarm] [502] Burglary Alarm Restore [Burglary Alarm Restore]
[503] Fire Alarm [Fire Alarm] [504] Fire Alarm Restore [Fire Alarm Restore]
[505] 24 Hour Alarm [24 Hour Alarm] [506] 24 Hour Alarm Restore [24 Hour Alarm Restore]
[507] Holdup Alarm [Holdup Alarm] [508] Holdup Alarm Restore [Holdup Alarm Restore]
[509] Gas Alarm
[Gas / Carbon Monoxide
Alarm]
[510] Gas Alarm Restore
[Gas / Carbon Monoxide
Restore]
[511] Heat Alarm [High Temperature Alarm] [512] Heat Alarm Restore
[High Temperature Alarm
Restore]
[513] Medical Alarm [Medical Alarm] [514] Medical Alarm Restore [Medical Alarm Restore]
[515] Panic Alarm [Panic Alarm] [516] Panic Alarm Restore [Panic Alarm Restore]
[517] Emergency Alarm [Emergency Alarm] [518] Emergency Alarm Restore [Emergency Alarm Restore]
[519] Sprinkler Alarm [Sprinkler Alarm] [520] Sprinkler Alarm Restore [Sprinkler Alarm Restore]
[521] Water Level Alarm [Water Level Alarm] [522] Water Level Alarm Restore [Water Level Alarm Restore]
[523] Freeze Alarm [Low Temperature Alarm] [524] Freeze Alarm Restore
[Low Temperature
Alarm Restore]
[525] Fire Supervisory [Fire Supervisory] [526] Fire Supervisory Restore [Fire Supervisory Restore]
[527] Zone Tamper [Zone Tamper] [528] Zone Tamper Restore [Zone Tamper Restore]
[529] Zone Fault [Zone Fault] [530] Zone Fault Restore [Zone Fault Restore]
[531] Fire Trouble [Fire Trouble] [532] Fire Trouble Restore [Fire Trouble Restore]
[533] Module Supervisory
[Module Supervisory
Trouble]
[534] Module Supervisory
Restore
[Module Supervisory Restore]
[535] General System Tamper [General System Tamper]
[536] General System Tamper
Restore
[General System Tamper
Restore]
[537] Wireless Device Low
Battery
[Wireless Device
Low Battery]
[538] Wireless Device Low Bat-
tery Restore
[Wireless Device Battery
Restore]
[539] Cross Zone/Police Code [Burglary Verified] [540] Burglary Not Verified [Burglary Not Verified]
[541] Duress Alarm [Duress Alarm] [542] Opening After Alarm [Disarmed After Alarm]
[543] Recent Closing
[Alarm Occurred After
Arming]
[544] Alarm Canceled [Alarm Canceled]
[545] Keypad Lockout [Keypad Lockout] [546] Exit Fault [Exit Fault]
[547] Partial Closing
[Armed With Zones
Bypassed]
[548] Zone Bypass [Zone Bypassed]
[549] Zone Unbypass [Zone Unbypassed] [550] Auto Arm Cancel [Automatic Arming Cancelled]
[551] Closing [Armed By] [552] Opening Label [Disarmed By]
[553] Special Closing [Armed] [554] Special Opening [Disarmed]
[555] Late to Open [Late to Open] [556] Delinquency [Delinquency]
29008218R001_NOVA_TL255GS_GS2055_V.2.5X_IM_ENG_NA_UL_ULC_FCC_IC_dft_03