User's Manual

6
1. Operate silence button.
2. Call emergency services or your fire department.
3. Immediately move outdoors or to an open door/window.
WARNING: Carefully review your Carbon Monoxide Installation/User Guide to determine the
necessary actions required to ensure your safety and ensure that the equipment is operating cor-
rectly. Incorporate the steps outlined in the guide into your evacuation plan.
2-Way/1-Way Audio Operation (SCW9057 only)
If programmed by the installer, this feature allows the monitoring station to initiate a 2-way audio
(talk/listen) or 1-way audio (listen-in only) session when an alarm has been received. This feature is
used to verify the nature of the alarm or determine the type of assistance required by the occupant.
NOTE: This feature can be initiated only by the monitoring station after an alarm has been
received. The user can not initiate a 2-way audio session.
Time & Date Programming and Temperature Display
Press [][6] then enter your master access code to enter
User Functions. Use the [<][>] buttons to find the menu
option, then press [
] to select. Enter the time in 24-hr. for-
mat (HH:MM), followed by the date (MM:DD:YY). Press [#] to
exit programming. If you are viewing a "Loss of Clock" trouble from within the trouble menu
([
][2]), press [] to directly enter Date and Time programming (see Trouble Conditions).
The SCW9055/57 panel and WT5500 keypad can also display the outdoor temperature (Faren-
heit or Celsius) from the 2-way outdoor siren. This feature must be enabled by your installer.
NOTE: Your installer may have programmed your system to display the time and date while the
keypad is idle. Press the [#] button to temporarily clear the date and time display if desired.
Bypassing Zones
Use the zone bypassing feature when you need access to a protected area while the system is
armed, or when a zone is temporarily out of service but you need to arm the system. Bypassed
zones will not be able to sound an alarm. As a result, bypassing zones reduces the level of
security. If you are bypassing a zone because it is not working, call a service technician imme-
diately so that the problem can be resolved and your system returned to proper working order.
Ensure that no zones are unintentionally bypassed when arming your system. Zones cannot be
bypassed once the system is armed. Bypassed zones (except for 24-hr zones) are automati-
cally cancelled each time the system is disarmed and must be bypassed again, if required,
before the next arming.
With the system disarmed:
Activating All Bypassed Zones
To remove bypass (all zones):
1. Press [
][1], then your access code.
2. Press [0][0].
3. To exit bypassing mode and return to the Ready state, press [#].
Recalling Bypassed Zones
To recall the last set of bypassed zones:
1. Press [
][1], then your access code.
2. Press [9][9].
1. Press [
] to enter the function menu. The keypad will display the
screen on the right.
2. Press [1] or [
].
3. If your system is programmed to require access codes the screen
on the right will be displayed. Enter your 4-digit access code.
4. Scroll to the desired zone number using the [<][>] keys, then
press [
] to select the zone or directly enter the 2-digit number of
the zone you wish to bypass (e.g., 0 5 for zone 5).
Press (*) for <>
Zone Bypass
Enter Your
Access Code
Scroll to <>
Bypass Zones