User's Manual
7
3. To exit bypassing mode and return to the Ready state, press [#].
Bypass Group
A Bypass Group is a selection of zones programmed into the system. If you bypass a group of
zones on a regular basis, you can program them into a Bypass Group, so that you do not have
to bypass each zone individually. Note that only one Bypass Group can be programmed at a
time.
To program a Bypass Group:
1. Press [
][1], then enter your access code.
2. Enter the 2-digit numbers (01-34) of the zones to be included in the Bypass Group or use the
[<][>] buttons to find the zone to be included in the Bypass Group, then press [
] to select
the zone.
3. To save the selected zone into the group, press [9][5].
4. To exit bypassing mode and return to the Ready state, press [#].
NOTE: If an access code is required to enter bypassing, only the master code and codes with
Supervisory enabled can set the Bypass Group.
To select a Bypass Group when arming the system:
1. Press [
][1], then your access code.
2. Press [9][1]. The next time the system is armed, the zones in this group will be bypassed.
3. To exit bypassing mode and return to the Ready state, press [#].
NOTE: A Bypass Group is only recalled if the system is armed/disarmed after programming the
Bypass Group.
NOTE: This feature is not to be used in UL Listed installations.
Trouble Conditions
When a trouble condition is detected, the Trouble ( ) indicator will turn on and the keypad will
beep every 10 seconds. Press the [#] button to silence the beeps. Press [
][2] to view the trouble
condition. The Trouble ( ) indicator will flash. Use the scroll [<][>] keys to view troubles.
Trouble Comments Action
Alternate
Communicator Trouble
Indicates SIM Card Lock, GSM Trouble, Ethernet Trouble,
Central Station Receiver Trouble, Supervision Trouble, and
SMS Config Trouble. Press
[<][>] to scroll through individ-
ual troubles.
Call for service.
For Ethernet Trouble
check LAN connec-
tions.
Service Required
(Press [1] for more infor-
mation)
Indicates Low Battery, System Trouble, System Tamper or RF
Jam detected.
Call for service.
Loss of AC Power If the building and/or neighbourhood has lost electrical
power, the system will continue to operate on battery power
for several hours.
Check AC
connection.
Call for service.
Telephone Line Fault The system has detected that the telephone line is discon-
nected.
Call for service.
Failure to
Communicate
The system attempted to communicate with the monitoring
station but failed. This may be due to a telephone line Fault.
Call for service.
Module/Sensor Fault The system is experiencing difficulties with one or more mod-
ule/sensor on the system. Continue to press [5] to navigate
through the zone, keypad, and siren fault menus.
Call for service.
Module/Sensor Tamper The system has detected a tamper condition with one or
more module/sensor on the system. Continue to press
[6] to
navigate through the zone, keypad, and siren tamper menus.
Call for service.
Module/Sensor Low Bat-
tery
The system has detected a low battery condition with one or
more module/sensor on the system. Continue to press
[7] to
display the zone(s), wireless key(s), keypad(s), siren(s) and
prox tag(s).
See section on Siren
Test. Call for service.
Loss of Time & Date If complete power was lost (AC and Battery), the time and
date will need to be re-programmed. Press
[].
Reprogram Time &
Date.