User's Manual
4
NOTE: For SIA CP-01 listed panels, the Stay Arming Exit Delay will be twice as long as the Away
Arming Exit Delay.
NOTE: If your system is installed in accordance with SIA CP-01 Standard for False Alarm
Reduction, then the security system will arm in the Stay Armed mode if the exit delay time expires
and no exit has been made.
Night Arming
To night arm the system when it has been armed in Stay mode, press [][1] at the keypad. All
interior zones will now be armed except for devices programmed as Night zones.
NOTE: Your installer can also program a function key on the keypad to allow you to arm the
system in Night mode. This allows Night arming to be activated by holding down the function
key for 2 seconds.
Night zones are only armed in Away mode; this permits limited movement within the premises
when the system is fully armed. Ensure that your installer has provided you with a list identifying
zones programmed as night zones.
When the interior zones are activated (i.e., [
][1]) you must enter your access code to disarm
the system in order to gain access to interior areas that have not been programmed as night
zones.
Silent Exit Delay
If the system is armed using the Stay button or using the "No Entry" Arming method ([][9]
[Access Code]), the keypad buzzer will be silenced and the exit time will be doubled for that
exit period only. (CP-01 only)
Away Arming
Close all sensors (i.e., stop motion and close doors). The Ready ( ) indicator should be on.
To arm, press and hold the Away button for 2 seconds and/or enter your access code or press
[
][0] to Quick Arm.
During the setting state (exit delay active) the Armed ( ) and Ready ( ) indicators will turn on,
and the keypad will sound one beep per second. You now have ___ seconds to leave the prem-
ises (please check with your installer to have this time programmed). A keypad buzzer, whose
pulsating rate is distinct, will sound during the last ten seconds of the exit delay to warn per-
son(s) that the exit delay is running out. To cancel the arming sequence, enter your access
code.
When the exit delay is completed, the alarm system is armed and this is indicated on the key-
pad display as follows: the Ready ( ) indicator will turn off, the Armed ( ) indicator will remain
on and the keypad will stop sounding.
NOTE: The system can also be armed/disarmed with a wireless key and with prox tags. Refer
to the "Proximity Tags" and "Two-Way Wireless Key" sections for more details.
NOTE: If your system is installed in accordance with SIA CP-01 Standard for False Alarm
Reduction, the following holds true: Violation and restoral, followed by a second violation of the
entry/exit zone before the end of the exit delay, will restart the exit delay.
Quick Exit
If the system is armed and you need to exit, use the Quick Exit function to avoid disarming and
rearming the system. Press and hold the Quick Exit button for 2 seconds or press [
][0].
You now have 2 minutes to leave the premises. When the door is closed again, the remaining
exit time is cancelled.
Siren Sounds After Away Arming
Audible Exit Fault
In order to reduce false alar
ms, the Audible Exit Fault is designed to notify you of an improper
exit when arming the system. If you fail to securely close the entry/exit door during the pro-
grammed exit delay period, the system will sound the alarm to indicate an improper exit (your
installer will tell you if this feature has been enabled on your system). If this occurs:
1. Re-enter the premises.
2. Enter your access code before the entry delay timer expires, to disarm the system.