User's Manual

Alarm Communicator Installlation Manual Area Label Programming
21
[8] SMS Command and Control Enabled Default (ON).
NOTE: Each telephone number can be programmed to receive different event notifications. When more than 1 number receives the
event, the system will send the message to phone number 1 first. Only 1 send attempt is made for each programmed number.
Notification, for each programmed telephone number can be enabled/disabled with Toggle Option [7].
AREA LABEL PROGRAMMING
Each Area label is up to 32 ASCII characters, including spaces. The label language is specified in Section [009].
[351] Account Label
Default (Security System);
The Account Label is up to 32 ASCII characters. It is sent at the beginning of every SMS message originating from the Communicator
module.This label is used to identify the system to the recipient of the SMS message.
[352] System Label
Default (System Area);
The System Label is up to 32 ASCII characters. It is used for notification messages that apply to the system.
NOTE: On single partition systems the System Label may be used for all messages.
[353] - [360] Partition 1- 8 Label
Default (Partition x);
Where x is a partition number from 1 - 8. Partition Labels are up to 32 ASCII characters. Labels are used for SMS notification messages
that apply to a specific partition on the system.
USER LABEL PROGRAMMING
[361] - [400] User 1 - 40 Label
Default (User x);
Where x is the User number from 1 - 40. User labels are used to identify a User for SMS notification messages that apply to a specific
user. There are 40 programmable User Labels. Each label is up to 16 ASCII characters. The label language is specified in Section [009].
ZONE LABEL PROGRAMMING
[401] - [464] Zone 1 - 64 Label
Default (Zone n);
Where n is a Zone number from 1 - 64. Zone Labels are up to 32 ASCII characters. Labels are used to identify the Zone for notification
messages that apply to a specific Zone. The label language is specified in Section [009]. Zone labels are numbered 1 - 64 and Zones are
numbered 1-128. No labels are assigned to Zones 65-128.
PANEL EVENT LABEL PROGRAMMING
[501] - [580] Event Labels
Default (see Default Label in Table 13 );
There are 80 programmable Event labels. Each label is pre programmed with the default text shown in Table 13 .
Each label is up to 32 ASCII characters (including spaces). The language is specified in Section [009].
Table 13: Panel Event Labels
Event [Section] Label Default Label Event [Section] Label Default Label
[501] Burglary Alarm [Burglary Alarm] [502] Burglary Alarm Restore [Burglary Alarm Restore]
[503] Fire Alarm [Fire Alarm] [504] Fire Alarm Restore [Fire Alarm Restore]
[505] 24 Hour Alarm [24 Hour Alarm] [506] 24 Hour Alarm Restore [24 Hour Alarm Restore]
[507] Holdup Alarm [Holdup Alarm] [508] Holdup Alarm Restore [Holdup Alarm Restore]
[509] Gas Alarm
[Gas / Carbon Monoxide
Alarm]
[510] Gas Alarm Restore
[Gas / Carbon Monoxide
Restore]
[511] Heat Alarm [High Temperature Alarm] [512] Heat Alarm Restore
[High Temperature Alarm
Restore]
[513] Medical Alarm [Medical Alarm] [514] Medical Alarm Restore [Medical Alarm Restore]
[515] Panic Alarm [Panic Alarm] [516] Panic Alarm Restore [Panic Alarm Restore]
[517] Emergency Alarm [Emergency Alarm] [518] Emergency Alarm Restore [Emergency Alarm Restore]
[519] Sprinkler Alarm [Sprinkler Alarm] [520] Sprinkler Alarm Restore [Sprinkler Alarm Restore]
[521] Water Level Alarm [Water Level Alarm] [522] Water Level Alarm Restore [Water Level Alarm Restore]
[523] Freeze Alarm [Low Temperature Alarm] [524] Freeze Alarm Restore
[Low Temperature
Alarm Restore]
[525] Fire Supervisory [Fire Supervisory] [526] Fire Supervisory Restore [Fire Supervisory Restore]
[527] Zone Tamper [Zone Tamper] [528] Zone Tamper Restore [Zone Tamper Restore]
[529] Zone Fault [Zone Fault] [530] Zone Fault Restore [Zone Fault Restore]