User's Manual

3G Alarm Communicator Installlation Manual Cellular Options
17
[222] Cellular Login User Name
Default ( )
Some network carriers require you to provide login credentials when connecting to an APN. Program your login User Name in this Sec-
tion. Format is up to 32 ASCII characters.
NOTE: This Section is not accessible via PC1616/PC1832/PC1864 keypad programming.
[223] Cellular Login Password
Default ( )
Some network carriers require you to provide login credentials when connecting to an APN. Program your login Password in this Sec-
tion.
Format is up to 32 ASCII characters.
[224] Cellular Test Transmission Time of Day
Default (9999)
Enter a 4 digit value using the 24-hour clock format (HHMM) to set the test transmission time of day. Valid range: 00-23 for the hours
(HH) and 00-59 for the minutes (MM).
NOTE: To disable the test transmission time of day enter 9999 or FFFF in this Section.
The internal date and time will be automatically programmed by the primary receiver only.
[225] Cellular Test Transmission Cycle
Default (000000)
This value represents the interval in between test transmissions in minutes. Valid range: 000000 - 999999 minutes. Once the unit has
sent the initial periodic test transmission, all future test transmissions will be offset by the programmed number of minutes. See Sec-
tions [026] - [029].
NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes will disable test transmission.
[226] Cellular Trouble Delay
Default (00)
This option is used to program the delay, in minutes, for reporting a Cellular Trouble Delay. Valid entries are 00 - FF. (e.g., for a 10 min-
ute Cellular Trouble Delay enter: 0A). There is no reporting delay if value is programmed as 00.
[682] Notification Zone 1 - 8 Toggle Options
The default for each Notification Zone Toggle is OFF.
[683] Notification Zone 9 - 16 Toggle Options
The default for each Notification Zone Toggle is OFF.
[684] Notification Zone 17 - 24 Toggle Options
The default for each Notification Zone Toggle is OFF.
[685] Notification Zone 25 - 32 Toggle Options
The default for each Notification Zone Toggle is OFF.
[686] Notification Zone 33 - 40 Toggle Options
The default for each Notification Zone Toggle is OFF.
[687] Notification Zone 41 - 48 Toggle Options
Table 10: Ethernet Test Transmission Interval
Test Transmission Interval Daily Weekly Monthly
Programmed Minutes 001440 010080 043200
Table 11: Notification Zone 1 - 8 Toggle
TOGGLE 01 02 03 04 05 06 07 08
ZONE
12345678
Table 12: Notification Zone 9 - 16 Toggle
TOGGLE 01 02 03 04 05 06 07 08
ZONE
9 10111213141516
Table 13: Notification Zone 17 - 24 Toggle
TOGGLE 01 02 03 04 05 06 07 08
ZONE
17 18 19 20 21 22 23 24
Table 14: Notification Zone 25 - 32 Toggle
TOGGLE 01 02 03 04 05 06 07 08
ZONE
25 26 27 28 29 30 31 32
Table 15: Notification Zone 33 - 40 Toggle
TOGGLE 01 02 03 04 05 06 07 08
ZONE
33 34 35 36 37 38 39 40
29007850R001_Shared_Review_updated_by_MM_04