3G2055-NA 4 HSPA/3G WIRELESS ALARM COMMUNICATOR _M M _0 TL255-NA d_ by ETHERNET/INTERNET ALARM COMMUNICATOR _u pd at e TL2553G-NA 29 00 78 50 R 00 1_ Sh ar ed _R ev ie w ETHERNET/INTERNET AND HSPA/3G/2G DUAL-PATH ALARM COMMUNICATOR v3.0 Installation Manual Warning: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer.
3G Alarm Communicator Installlation Manual TABLE OF CONTENTS Warning: Installer Please Read Carefully . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Communicator Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
G Alarm Communicator Installlation Manual Warning: Installer Please Read Carefully WARNING: INSTALLER PLEASE READ CAREFULLY Motion Detectors The Warnings on this page contain vital information. As the only individual in contact with system users, it is the installer’s responsibility to bring each item in this Warning to the attention of all users of this system. Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions.
Keypad Data Display 3G Alarm Communicator Installlation Manual GENERAL INFORMATION Domain Name Service (DNS) programming is not permitted in UL/ULC listed systems. KEYPAD DATA DISPLAY • Section-Toggle Options: The number is displayed when Toggle is ON, the number is not displayed when Toggle is OFF. (e.g., Toggle Options displays: “[--3--6--]”. Options 3 and 6 are ON, all others are OFF). Pressing keys 1 through 8 will alternately turn the Toggle ON and OFF.
3G Alarm Communicator Installlation Manual General Information COMMUNICATOR TECHNICAL SPECIFICATIONS GENERAL INFORMATION by _M M _0 4 All versions of the HSPA/3G and Ethernet Alarm Communicator, operate on a HSPA/3G network and are housed inside the Self Contained Wireless (SCW) 9055/9057. The Communicators use an Internal Antenna only. (Author’s Note: Underlined bu Aun. 2clrfy.
Ratings 3G Alarm Communicator Installlation Manual RATINGS Table 4: Communictor Electrical Ratings 3G2055 Cellular Only Model Power Supply Ratings Input Voltage Current Consumption Standby Current (@ 3.7V) Alarm (Transmitting) Current) Antenna Specifications Dual band Antenna Environmental Specifications Operating Temperature Humidity Mechanical Specifications Board Dimensions (mm) Weight (grams) TL2553G Ethernet and Cellular TL255 Ethernet Only 3.5 / 3.9 / 4.
3G Alarm Communicator Installlation Manual Encryption NOTE: Following initial installation, you can log in to the Connect24 website at any time to re-configure the Communicator remotely, using the account created for this installation. For more information, refer to the Connect24 website. Before leaving the installation site, the Communicator TL2553G or TL255 shall be connected via an APPROVED (acceptable to the local authorities) Network Interface Device (NID) (e.g.
Inserting/Removing the SIM Card 3G Alarm Communicator Installlation Manual INSERTING/REMOVING THE SIM CARD 1.Remove the front cover of the SCW Control Panel to access SIM card holder. 2.Remove power from the SCW and disconnect the backup battery connections. 3.On the SIM card holder push gently to slide the cover towards OPEN as indicated by the arrow on SIM holder. This will unlatch the SIM card holder on the side furthest from edge of the Communicator. See Figure 1. 4.
3G Alarm Communicator Installlation Manual Label Programming for SMS Message 6. Panel Section [382]: Toggle Option [5], ‘GS/IP Module Enabled’, must be set to ON. 7. Panel Section [401]: Toggle Option [1] must be set to ON in order to perform panel DLS session through Cellular or Ethernet data chanel. NOTE: Keep a record of the SIM card telephone number, it is required by users for SMS Command and Control functions.
System Options 3G Alarm Communicator Installlation Manual ETHERNET/CELLULAR PROGRAMMING OPTIONS The Programming Sections described in this document can be viewed at the SCW LCD. To start programming enter: [*][8][installer code] [851][# # # ], Where # # # is the 3 digit Section number referenced in this section. The Programming Worksheets at the end of this document can be used to record the new values when programming changes have been made from the default values.
3G Alarm Communicator Installlation Manual System Options [005] System Toggle Options [1] Ethernet Receiver 1 Supervised Default (OFF) (TL255/TL2553G only). ON: Ethernet Receiver 1 will be supervised and heartbeats will be sent to Ethernet Receiver 1 based on the supervision interval programmed in Section [004]. OFF: Ethernet Receiver 1 will not be supervised. When disabled, heartbeat 1 is sent to the Ethernet receiver once every hour, regardless of supervision type (heartbeat 1 or 2).
Programming Options 3G Alarm Communicator Installlation Manual ev ie w _u pd at e d_ by _M M _0 4 [006] System Toggle Options 2 [1] Ethernet 1 Receiver Enabled. Default (ON) (OFF for 3G2055). ON: Ethernet Receiver 1 is enabled. OFF: Ethernet Receiver 1 is disabled. [2] Ethernet 2 Receiver Enabled. Default (ON) (OFF for 3G2055). ON: Ethernet Receiver 2 is enabled. OFF: Ethernet Receiver 2 is disabled. [3] Reserved. (OFF). [4] Cellular 1 Receiver Enabled. Default (ON).
3G Alarm Communicator Installlation Manual Communications Reporting Codes ing your firewall with this port is not required. Valid range: 0000-FFFF. NOTE: If Section [006] Toggle Option [7] is ON. DLS will use the Primary path for session. If Section [006] Toggle Option [7] is OFF DLS will use the Ethernet path, if available. [020] Installer Code Default (CAFE) Program your installer code for this Communicator module. The installer code will be required when programming the Communicator module.
Ethernet Receiver 1 Options 3G Alarm Communicator Installlation Manual [026] Ethernet 1 Transmission Default (FF) Program 00 to disable this event transmission or FF to enable. See System Test Options (above) for details on settings. [027] Ethernet 2 Transmission Default (00) Program 00 to disable this event transmission or FF to enable. See System Test Options (above) for details on settings. [028] Cellular 1 Transmission Default (FF) Program 00 to disable this event transmission or FF to enable.
3G Alarm Communicator Installlation Manual Ethernet Options [112] Ethernet Receiver 2 DNIS Default (000000) The DNIS is used in addition to the account code to identify the Communicator module at the central station. Valid range: 000000 099999. Value is entered as leading 0 followed by the 5 digit DNIS. Format is BCD. NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS. [113] Ethernet Receiver 2 Address Default (000.000.000.
Cellular Receiver 2 Options 3G Alarm Communicator Installlation Manual [203] Cellular Receiver 1 Address Default (000.000.000.000) Enter the Cellular Receiver 1 IP address. This information will be provided by your central station system administrator. Each 3 digit segment of the address must be within a valid range of 000-255. NOTE: When a valid IP address has been entered, the Cellular is enabled and will communicate events over the Cellular channel.
3G Alarm Communicator Installlation Manual Cellular Options [222] Cellular Login User Name Default ( ) Some network carriers require you to provide login credentials when connecting to an APN. Program your login User Name in this Section. Format is up to 32 ASCII characters. NOTE: This Section is not accessible via PC1616/PC1832/PC1864 keypad programming. [223] Cellular Login Password Default ( ) Some network carriers require you to provide login credentials when connecting to an APN.
Receiver Diagnostic Testing 3G Alarm Communicator Installlation Manual The default for each Notification Zone Toggle is OFF. Table 16: Notification Zone 41 - 48 Toggle TOGGLE ZONE 01 41 02 42 03 43 04 44 05 45 06 46 07 47 08 48 06 54 07 55 08 56 06 62 07 63 08 64 [688] Notification Zone 49 - 56 Toggle Options The default for each Notification Zone Toggle is OFF.
3G Alarm Communicator Installlation Manual System Reset Defaults This Section will display the unique 15 digit International Mobile Equipment Identity (IMEI) of the radio. Format is: Reporting Body Identifier (2 digits), Allocation Number (4 digits); Final Assembly Code (2 digits); Serial Number (6 digits); and a check digit. [998] MAC Address This Section will display the unique12 digit, hexadecimal number assigned as the Media Access Control (MAC) address of the device.
3G Alarm Communicator Installlation Manual 29 00 78 50 R 00 1_ Sh ar ed _R ev ie w _u pd at e d_ by _M M _0 4 System Reset Defaults 20
3G Alarm Communicator Installlation Manual System Options ETHERNET/CELLULAR PROGRAMMING WORKSHEETS SYSTEM OPTIONS [022] Communications Format [001] Ethernet IP Address Default (04) Program 03 (CID), 04 (SIA). Default (000.000.000.000) |____|____| |____|____|____||____|____|____||____|____|____|____|____|____| [023] Panel Absent Trouble [002] Ethernet IP Subnet Mask Default (FF); Program 00 disable or FF enable. Default (255.255.255.
Ethernet Options 3G Alarm Communicator Installlation Manual [112] Ethernet Receiver 2 DNIS [213] Cellular Receiver 2 Address Default (000000) Valid range: 000000 - 0FFFFF. Default (000.000.000.000) Valid segment range: 000-255 |____|____|____|____|____|____| |____|____|____||____|____|____||____|____|____|____|____|____| [113] Ethernet Receiver 2 Address [214] Cellular Receiver 2 Port Default (000.000.000.000) Default (0BF5/3061) Valid range: 0000 - FFFF.
3G Alarm Communicator Installlation Manual Receiver Diagnostic Testing [689] Notification Zone 57 - 64 Toggle Options |____|____|____|____|____|____|____|____| 57 58 59 60 61 62 63 64 RECEIVER DIAGNOSTIC TESTING [901] Diagnostic Test Transmission |___| [1] Ethernet 1 Default (OFF). |___| [2] Ethernet 2 Default (OFF). |___| [3] Cellular 1 Default (OFF). [681] Notification Event Toggle |___| [4] Cellular 2 Default (OFF). |____| [1] Alarm/Restore Default (OFF). |____| [2] Tamper/Restore Default (OFF).
End User Licence Agreement 3G Alarm Communicator Installlation Manual END USER LICENCE AGREEMENT IMPORTANT - READ CAREFULLY: DSC Software purchased with or without Products and Components is Copyrighted and is purchased under the following license terms: 29 00 78 50 R 00 1_ Sh ar ed _R 4 _0 M _M by d_ _u pd at e ev ie By installing, copying, downloading, storing, accessing, or otherwise using the SOFTWARE PRODUCT, You agree unconditionally to be bound by the terms of this EULA, even if
3G Alarm Communicator Installlation Manual Limited Warranty LIMITED WARRANTY 29 00 78 50 R 00 1_ Sh ar ed _R 4 _0 M _M by d_ ev ie Warranty Procedure To obtain service under this warranty, please return the item(s) in question to the point of purchase. All authorized distributors and dealers have a warranty program. Anyone returning goods to Digital Security Controls must first obtain an authorization number.
FCC Compliance Statement CAUTION: Changes or modifications not expressly approved by the Digital Security Controls could void your authority to use this equipment. 4 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.