WS4920 v1.0 Installation Instructions NOTE: Use these instructions in conjunction with the installation manual of the alarm panel with which this equipment is intended to be used. WARNING: READ and SAVE These Instructions! Follow All WARNINGS AND INSTRUCTIONS specified within these instruction and/or on the equipment.
IMPORTANT: SAFETY INSTRUCTIONS for WS4920 WIRELESS REPEATER This equipment, WS4920 WIRELESS REPEATER 1.0 shall be used installed and used within an environment that provides the pollution degree max 2 and overvoltages category II NON HAZARDOUS LOCATIONS, indoor only.
Introduction The WS4920 is a wireless repeater designed to extend the range of DSC one-way wireless transmitters and to improve signal quality between the transmitter and the receiver. Use the WS4920 to remedy transmission problems caused by excessive noise or other interference, or by long distances between devices and receivers. Up to 4 repeaters can be installed per alarm system. The WS4920 is compatible with all DSC 433 MHz one-way wireless transmitters, receivers and alarm panels.
.Plug AC adaptor into wall outlet. D.Enroll with alarm panel E. Placement test with alarm panel (Detects interference between repeater and panel) F. Enroll/Placement test wireless devices with repeater G. Permanently mount WS4920. AC Terminals NOTE: When enrolling and placement testing the WS4920 with the alarm panel, refer to the panel installation instructions for the appropriate programming sections. A: Temporarily Mount WS4920 Select a suitable location for the repeater.
D: Enrolling the WS4920 The WS4920 has two Electronic serial numbers (ESN) that must be entered into the alarm panel during enrollment. The first communicates supervisory and tamper status. The second identifies battery status (see note below). To quick enroll the WS4920 (available on selected alarm panels): 1. Enter Wireless Enrollment mode on alarm panel (see panel installation instructions). 2.Tamper WS4920 to transmit first ESN. 3.Confirm ESN on alarm panel. The panel prompts for zone number. 4.
ment test mode using the first repeater serial number. The repeater placement test results are sounded through the alarm panel siren. •If “BAD Zone Placement” tone sounds, reposition device and trip zone again. Continue until “GOOD Zone Placement” tone sounds. NOTE: Although good results may be obtained on the repeater, bad results are still possible from the alarm panel due to collisions. 5.Use above procedure to enroll and placement test other zones. 6.
Limited Warranty Digital Security Controls warrants that for a period of 12 months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot.
FCC COMPLIANCE STATEMENT CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY DIGITAL SECURITY CONTROLS COULD VOID YOUR AUTHORITY TO USE THIS EQUIPMENT. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception.