Notes for using Private, Corporate, and High Speed Data Networks:
Network access and domain access policies shall be set to restrict unauthorized network access, and spoofing
or Denial of Service (DoS) attacks. Select an Internet Service Provider (ISP) that has redundant servers/sys-
tems, back-up power, routers with firewalls enabled, and methods to identify and protect against DoS attacks
(e.g., via spoofing).
Notes for using Public Switched and Wireless Data Networks:
Communication channels shall be facilitated such that the Communicator will restrict unauthorized access,
which could otherwise compromise security. Communicators shall be located in secured areas.
For ULC Residential fire and burglary applications the TL260GS-RS can be used as primary communication
channel via either GSM or Ethernet or as a back-up in conjunction with the Digital Alarm Communicator
Transmitter (DACT). Test transmission every 24hours shall be enabled on each channel.
For ULC Commercial Fire and Burglary applications the GS2060-RS/TL260GS-RS can be used as a passive
communication module with the following Security Levels:
P1 (each channel GSM or Ethernet is independent),
P2 (GSM and Ethernet in back-up configuration, panel Section [851][005] Toggle Option [5] OFF),
P3 (GSM and Ethernet in redundant configuration, panel Section [851][005] Toggle Option [5] ON).
The module can be also used as an Active communication system with the Security Levels A1-A4 (each
channel GSM or Ethernet independent or together in a back-up/redundant configuration). For Active Line
Security systems AES128 bit encryption shall be enabled at the monitoring station receiver and the supervi-
sion heartbeat rate shall be set as 90 seconds (panel Section [851] [004] = 005A/90). The supervision win-
dow at the Signal Receiver Centre (SRC)'s receiver shall be programmed as maximum 00B4/180 seconds.
For UL Residential fire and burglary applications the GS2060-RS andTL260GS-RS can be used as primary
communication channel via either GSM or Ethernet, or as a back-up in conjunction with the DACT (30 day
test transmission is required on each channel).
For UL Commercial Burglary applications the TL260GS-RS module can be used as Dual Signalling Line
communication system (GSM and Ethernet channels used in redundant configuration), Standard Line Secu-
rity and as Encrypted Line Security.
The supervision heartbeat shall be enabled (panel Section [851] [005] Toggle Option [1] (Ethernet) and/or
Toggle Option [2] (GSM) shall be ON), Toggle Option [3] (Supervision Type) shall be ON and the supervision
heartbeat rate shall be selected as 0087/135 seconds Option [004] = 0087. The supervision window at the
supervising station shall be maximum 00C8/200 seconds. For Encrypted Line Security systems the encryp-
tion AES128 bit shall be enabled at the monitoring station receiver.
For UL Commercial Burglary installations, the GS2060-RS is listed as a primary (sole) communication
means (heartbeat must be enabled) or for supplementary (back-up) use in conjunction with a Plain Old Tele-
phone Service (POTS) line (dialer). When the heartbeat transmission over the Ethernet or GPRS/GSM net-
work is enabled, using the TL260GS-RS with a compatible control unit listed for standard/encrypted line
security, it can provide line security for the alarm system over the primary line.
The TL260GS-RS is also suitable to be used with a compatible control unit listed for dual line security trans-
mission when used in conjunction with a Digital Alarm Communicator Transmitter (DACT) or a Public
Switched Data Network (PSDN) transmitter, where the PSDN provides the line security and is the primary
line. In this mode, alarm signals are required to be sent simultaneously over both communication methods.
RatingsCompatibility
Table 1: Communicator Ratings
Model
GS2060-RS
GPRS/GSM only
TL260-RS
Ethernet Only
TL260GS-RS
Ethernet &GPRS/GSM
POWER SUPPLY RATINGS
Input Voltage
13.6V DC:
The panel Bell output shall be derated:
700mA - (Communicator mA) = (derated Bell output).
CURRENT CONSUMPTION
Standby Current
70mA @ 13.66V 80mA @ 13.66V 100mA @ 13.64V
Alarm (Transmitting) Current
4000mA @ 13.65V 4000mA @ 13.65V 400mA @ 13.64V
Operating Frequency
Quad band 850MHz, 900MHz, 1800MHz, 1900MHz
Typical Antenna Gain
2dBi
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature C - 4C (32°F- 12F)
Humidity 5% ~ 93% relative humidity, non-condensing
MECHANICAL SPECIFICATIONS
Board Dimensions (mm) 100 × 150 × 15 100 × 150 × 18 100 × 150 × 15
Weight (grams) with bracket 310 290 320
Table 2: Compatible Receivers, and Power Panels
Communicator
Receiver/
Panel
Description
GS2060-RS
TL260-RS
TL260GS-RS
Receiver
Sur-Gard System I Receiver, version 1.30+
Sur-Gard System II Receiver, version 2.10+
Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
Power Panel
Power Series PC1616, version 4.5+
Power Series PC1832, version 4.5+
Power Series PC1864, version 4.5+