User's Manual

20
[102] Ethernet Receiver 1 DNIS
Default (000000)
The Dialled Number Information Service (DNIS) is used in addition to the Account Code to identify the Communica-
tor module at the central station. Valid range: 000000 - 099999. Value is entered as a leading 0 followed by the 5
digit DNIS. Format is Binary Coded Decimal (BCD.
NOTE: Each Ethernet/GPRS receiver must be programmed with a unique DNIS.
[103] Ethernet Receiver 1 Address
Default (127.000.000.001)
The default address enables the Communicator to operate in
Unattended Mode
.
Unattended Mode is used when a receiver is not available and the unit is required to perform DLS sessions. Typi-
cally used where the customer programs the control panel daily due to access control and still wants to receive
alarms without buying extra hardware (receiver) or software.
NOTE: When a valid IP address has been programmed, Ethernet Receiver 1 is enabled and will commu-
nicate events over the Ethernet channel.
Ethernet Receiver 1 and GPRS Receiver 1 may be configured to communicate to the same central station receiver.
To configure the device to operate using this Common Receiver Mode functionality, program Ethernet Receiver 1
and GPRS Receiver 1, IP address and port number with identical values.
NOTE: When operating in Common Receiver Mode, Ethernet Receiver 1 account code will be used for
Ethernet and GPRS.
[104] Ethernet Receiver 1 Remote Port
Default (0BF5/3061)
This Section determines the remote port of Ethernet receiver 1. Valid range: 0000 - FFFF.
[105] Ethernet Receiver 1 Local Port
Default (0BF4/3060)
Use this Section to set the value of the local outgoing port. Set the value of this port when your installation is
located behind a firewall and must be assigned a particular port number as determined by your central station sys-
tem administrator. Valid range: 0000 - FFFF.
[106] Ethernet Receiver 1 Domain Name
Default ()
Enter the Domain Name as 32 ASCII characters.
Programming this Section is not permitted on a UL/ULC listed system.
Ethernet Receiver 2 Options
[111] Ethernet Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. The account code is used
when transmitting heartbeat signals to the central station receiver. Signals received from the control panel will use
the control panel account number. Valid range: 000000000
1
- FFFFFFFFF
E
.
Programming this Section as all
0
or all
F
will cause a Module Configuration Trouble (yellow LED=12 flashes).
NOTE: If both Ethernet Receiver 2 and GPRS Receiver 2 are the same receiver (IP and port number are
identical), Ethernet Receiver 2 account will be used for Ethernet and GPRS.
[112] Ethernet Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the Communicator module at the central station. Valid
range: 000000 -
0
99999. Value is entered as leading
0
followed by the 5 digit DNIS. Format is BCD.
NOTE: Each Ethernet/GPRS receiver must be programmed with a unique DNIS.
[113] Ethernet Receiver 2 Address
Default (000.000.000.000)
Programming the Ethernet receiver 2 IP address with 000.000.000.000 will disable Ethernet.
Enter the Ethernet receiver 2 IP address. This address will be provided by your central station system administrator.
Format is 4 fields, each field is a 3 digit decimal. Valid range: 000-255.
NOTE: When a valid IP address has been programmed, Ethernet Receiver 2 is enabled and will commu-
nicate events over the Ethernet channel.
Ethernet Receiver 2 and GPRS Receiver 2 may be configured to communicate to the same central station receiver.
To configure the device to operate using this common receiver mode functionality, program the Ethernet Receiver 2
and GPRS Receiver 2, IP address and port number with the same values. When operating in common receiver
mode the Ethernet Receiver 2 account code will be used for communications over Ethernet and GPRS.
NOTE: Do not program Ethernet Receiver 1 and Ethernet Receiver 2 to communicate to the same
receiver.
[114] Ethernet Receiver 2 Remote Port
Default (0BF5/3061)
This Section is used to program the port number used by Ethernet Receiver 2. Set the value of this port when your
installation is located behind a firewall, and must be assigned a particular port number as determined by your cen-
tral station system administrator. Valid range: 0000 - FFFF.
NOTE: Do not program Ethernet Receiver 1 and Ethernet Receiver 2 Port with the same value.
[115] Ethernet Receiver 2 Local Port
Default (0BF9/3065);
Use this Section to program the value of the local outgoing port. You can set the value of this port when your instal-
lation is located behind a firewall and must be assigned a particular port number as determined by your network
administrator. Valid range: 0000 - FFFF.
NOTE: Do not program Ethernet Receiver 1 and Ethernet Receiver 2 Port with the same value.