User's Manual

16
[008] DNS Server IP 2
Programming this Section is not permitted on a UL/ULC listed system.
Default (000.000.000.000)
Enter the IP address for DNS Server 2. Format is 4 fields, each field is a 3 digit decimal. Valid range: 000-255.
NOTE: If no value is programmed and DHCP is used, the DHCP Server will assign this value. If an
address is programmed and DHCP is used, the address that you program will be used instead of the
DHCP address.
[009] Language
Default (01)
NOTE: Immediately after programming this Section, perform a Default Languages in Section [999][11] to
have programmable labels available in the selected language. Programming this Section with an invalid
language number will default to English [01]. Connect24 will automatically update all programmable lan-
guage labels when this Section is changed.
[010] System Toggle Options 3
Default (OFF)
[1] Two way Audio over GSM.
ON: Two way audio over the GSM Voice channel is enabled.
OFF: Two way audio over the GSM Voice channel is disabled.
[2]-[8] Reserved. Default (OFF)
Programming Options
[011] Installer Code
Default (CAFE)
Program your installer code for this Communicator module. The installer code will be required when programming
the Communicator module. Valid range: 0000 - FFFF.
[012] DLS Incoming Port
Default (0BF6/3062);
The DLS Incoming Local Port (listening port) is the port DLS IV will use when connecting to the Communicator. If a
router or gateway is used, it must be programmed with a Transmission Control Protocol (TCP) port forward for this
port to the Communicator module IP address. Valid range: 0000-FFFF.
[013] DLS Outgoing Port
Default (0BFA/3066)
The DLS Outgoing Port is used for outgoing session to DLS IV after an SMS request has been sent to the Commu-
nicator. Use this Section to set the value of the local outgoing port. The value must be changed if the Communicator
is located behind a firewall and must be assigned a particular port number, as determined by your network adminis-
trator. In most cases, changing the default value or configuring your firewall with this port is not required. Valid
range: 0000-FFFF.
NOTE: If Section [006] Toggle Option [7] is ON. DLS will use the primary path for session. If Section
[006] Toggle Option [7] is OFF DLS will use the Ethernet path, if available.
[020] Time Zone
Default (00)
Use Offset Hours column to find your local time zone offset from GMT/UTC. Record the two digit HEX value
from the HEX column on same row. Program this HEX value as your Time Zone. Valid range is 00 - FF.
Table 8: Programming Label Languages
OPT Language OPT Language OPT Language OPT Language
00 Reserved 08 Czech 16 Turkish 24 Lithuanian
01 English 09 Finnish 17 Reserved 25 Ukrainian
02 Spanish 10 German 18 Croatian 26 Slovak
03 Portuguese 11 Swedish 19 Hungarian 27 Serbian
04 French 12 Norwegian 20 Romanian 28 Estonian
05 Italian 13 Danish 21 Russian 29 Slovenian
06 Dutch 14 Hebrew 22 Bulgarian 30 - 99 Reserved
07 Polish 15 Greek 23 Latvian
Table 9: Time Zone Offset
HEX
Offset
Hours
Std
Abbrev
Location HEX
Offset
Hours
Std
Abbrev
Location
01 -12
BIT Baker Island Time
47 +5.5
IST Indian Standard Time
05 -11
NUT Niue Time
48 +5.75
NPT Nepal Time
SST Somoa Standard Time
49 +6
XJT Xinjiang Standard Time
09 -10
HAST Hawaii-Aleutian Standard Time EKST East Kazakhstan Standard Time
THAT Tahiti Time LKT Sri Lanka Time
TKT Tokelau Time VOST Vostok Time
CKT Cook Island Time OMSK Omsk Standard Time
0B -9.5
MIT Marquesas Island Time NOVT Novosibirsk Time
0D -9
AKST Alaska Standard Time BTT Bhutan Time
GIT Gambier Island Time BIOT British Indian Ocean Time