User's Manual
Table Of Contents
- t6y
- t6y
- RFK5501/5500-433 v1.1
- Installation Instructions, Instrucciones de instalación
- English, Español
- English, Español
- English, Español
- English
- Installation Instructions
- Installation Instructions
- •PC580
- •PC585
- •PC1555MX
- •PC1565
- •PC1616
- •PC1832
- •PC1864
- •PC5005
- •PC5008
- •PC5010
- •PC5015
- •PC5016
- •PC5020
- •PC5020
- •PC5020
- •PC5020
- •One Power keypad
- •Keypad inner door labels
- •Four mounting screws
- •1 tamper switch
- •2 end-of-line resistors
- •Installation Instructions
- 1. Insert a flat head screwdriver into the provided slot (first of two)
- 2. Move screwdriver toward the back plastic and lift as in the below diagram. This will unhook one side of the front plastic.
- 3. Repeat step # 1 and 2 on the second provided slot to disconnect the front plastic and allow access for wiring.
- 2. Place keypad into hooks on the backplate and swing down to engage.
- 3. Run wire through wiring slot or knockouts. Connect Keybus and PGM/Zone wiring to keypad. Place tamper switch into tamper hole on backplate.
- 4. Remove keypad from hooks. Place keypad into backplate, ensure the wire is pushed back into the wall as much as possible. Route the wire inside the keypad ensuring high components are avoided. Snap the front assembly closed, ensuring that there is ...
- 2. Connect the four Keybus wires from the control panel (red, black, yellow and green) to the keypad terminals. Refer to diagram:
- 3. If programmed as an input, you can connect a device - such as a door contact - to the ‘P/Z’ terminal of the keypad. This eliminates the need to run wires back to the control panel for the device. To connect the zone, run one wire from the devi...
- 4. If the ‘P/Z’ terminal is programmed as an output, the output follows the PGM programmed in Section [080]. A small relay, buzzer or other DC operated device may be connected between the positive supply voltage and the ‘P/Z’ terminal (maximu...
- 2. Connect the AC transformer.
- 2. Press [000] for Keypad Programming
- 3. Press [0] for Partition and Slot Assignment
- 4. Enter the 1st digit (0 to 8 for partition assignment)
- 5. Enter the 2nd digit (1 to 8 for slot assignment supervision)
- 6. Press the [#] key twice to exit programming.
- 7. After assigning all keypads, perform a supervisory reset by entering [Q][8][Installer’s Code][902] and wait for 60 seconds.
- 8. Press the [#] key to exit programming after 60 seconds.
- 2. Use the arrow keys (<>) to move the underline bar underneath the letter to be changed.
- 3. Press the number keys [1] to [9] corresponding to the letter you require. The first time you press the number the first letter will appear. Pressing the number key again will display the next letter.
- [1] - A, B, C, 1
- [4] - J, K, L, 4
- [7] - S, T, U, 7
- [0] - Space
- [2] - D, E, F, 2
- [5] - M, N, O, 5
- [8] - V, W, X, 8
- [8] - V, W, X, 8
- [3] - G, H, I, 3
- [6] - P, Q, R, 6
- [9] - Y, Z, 9,0
- [9] - Y, Z, 9,0
- 4. When the required letter or number is displayed use the arrow keys (<>) to scroll to the next letter.
- 5. When you are finished programming the Zone Label, press the [Q] key, scroll to “Save,” then press [Q].
- 6. Continue from Step 2 until all Labels are programmed.
- 2. Use the [<][>] keys to scroll to either Brightness Control or Contrast Control.
- 3. Press [Q] to select the setting you want to adjust.
- 4. a) ‘Brightness Control’: There are multiple backlighting levels. Use the [<][>] keys to scroll to the desired level. b) ‘Contrast Control’: There are 10 different display contrast levels. Use the [<][>] keys to scroll to the desired contra...
- 5. To exit, press [#].
- 2. Use the [>] key to move through the 4 different backlighting levels.
- 3. The level is automatically saved when you press [#] to exit.
- 2. Use the [<][>] keys to scroll to Buzzer Control.
- 3. There are 21 different levels, use the [<][>] keys to scroll to the desired level.
- 4. To exit, press [#].
- 2. Use the [<] key to move through the 21 different buzzer levels.
- 3. The level is automatically saved when you press [#] to exit.
- Partition Assignment (0=Global Keypad)
- Slot Assignment
- 1 to 8
- [1]
- Function Key 1 Assignment
- 00 to 32
- 03
- Stay Arm
- [2]
- Function Key 2 Assignment
- 00 to 32
- 04
- Away Arm
- [3]
- Function Key 3 Assignment
- 00 to 32
- 06
- Chime On/Off
- [4]
- Function Key 4 Assignment
- 00 to 32
- 14
- Sensor Reset
- [5]
- Function Key 5 Assignment
- 00 to 32
- 16
- Quick Exit
- [00] - Null
- [08] - Bypass Mode
- [16] - Quick Exit
- [26] - Time & Date Program
- [01] - Partition 1 Select
- [09] - Trouble Display
- [17] - Activate Stay/Away
- [27] - Partition 3 Select
- [02] - Partition 2 Select
- [10] - Alarm Memory
- [18] - *Global Away Arm
- [28] - Partition 4 Select
- [03] - Stay Arm
- [11] - User Programming
- [19] - Command Output 3
- [29] - Partition 5 Select
- [04] - Away Arm
- [12] - User Functions
- [21] - Command Output 4
- [30] - Partition 6 Select
- [05] - No Entry Arm
- [13] - Command Output 1
- [22] - *Global Disarming
- [31] - Partition 7 Select
- [06] - Chime On/Off
- [14] - Command Output 2
- [23] - Bypass Recall
- [32] - Partition 8 Select
- [07] - System Test
- [15] - *Global Stay Arm
- [24] - Bypass Group Recall
- [33] - Local PGM Activate
- *Available only on the PC1616/PC1832/PC1864 version 4.2 or higher.
- [001] to [064]
- 1 to 64
- [101] to [108]
- 1 to 8
- [00] - Null
- [07] - System Test
- [17] - Activate Stay/Away
- [27] - Disarm
- [03] - Stay Arm
- [13] - Command Output 1
- [18] - Global Away Arm
- [28] - Fire Alarm
- [04] - Away Arm
- [14] - Command Output 2
- [19] - Command Output 3
- [29] - Auxiliary Alarm
- [05] - No Entry Arm
- [15] - Global Stay Arm
- [21] - Command Output 4
- [30] - Panic Alarm
- [06] - Chime On/Off
- [16] - Quick Exit
- [22] - Global Disarm
- [31] - Local PGM Activate
English, Español
WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer.
NOTE: These instructions shall be used in conjunction with the system Installation Manual of the Control Panel with which this equipment is intended to be used.
ATENCIÓN: Consulte el Manual de instalación del sistema para obener información sobre las limitaciones del uso y funciones del producto, así como las limitaciones de la responsabilidad del fabricante.
NOTA: Estas instrucciones deberán utilizarse conjuntamente con el Manual de instalación del sistema del Panel de control con el que se vaya a utilizar este equipo.
RFK5501/5500-433 v1.1
Installation Instructions, Instrucciones de instalación
123
456
78
0
*
#
9
29007608R001