User's Manual

11
Walk Test
Walk Test mode allows you test the operation of each detector in the system. While in Walk Test
mode, the Ready, Armed, and Trouble LED's will flash to indicate that the Walk Test is active. The
Walk Test can be terminated at anytime by re-entering [Master Code] on the key-
pad. The system will also automatically terminate the Walk Test on completion, it will annunciate
with an audible warning (5 beeps every 10 seconds), beginning five minutes before the termina-
tion of the test.
1. Before testing, ensure that the system is disarmed and the Ready light is on.
2. Press and close all zones to return the system to the Ready state.
3. Perform a System Test by following the steps in the previous section.
4. Press [Master Code] to initiate the Walk Test
5. To test the zones, activate each detector in turn (e.g., open each door/window or walk in
motion detector areas).
The System will display the following message when each zone (detector) is activated:
‘Secure System Before Arming < >’, or ‘Secure or Arm System’. Use the buttons to
view which zones are open. The message will disappear when the zones are closed.
Allowing Computer Access To Your System
Occasionally, your installer may need to send information to or retrieve information from your
security system. Your installer will do this by having a computer call your system over the tele-
phone line. You may need to prepare your system to receive this ‘downloading’ call.
To do this:
Press [Master Code] at the keypad. This allows downloading for a limited period
of time. During this time, the system will answer incoming downloading calls. For more informa-
tion on this feature, please ask your installer.
Reference Sheets
Fill out the following information for future reference and store this guide in a safe place.
System Information
Enabled?
FIRE AUXILIARY PANIC
For Service
Central Station Information
Account#: ___________________ Telephone#: __________________
Installer Information:
Company: ___________________ Telephone#: __________________
If you suspect a false alarm signal has been sent to the central monitoring station, call
the station to avoid an unnecessary response.
The Entry Delay Time is _______ seconds.
The Exit Delay Time is _______ seconds.