User's Manual
8
Zone Bypassing Attribute
This attribute allows the user to manually bypass zones if bypassing requires an access code.
Bell Squawk Attribute
This attribute is used to determine whether an access code should generate an arming/disarm-
ing squawk when the away function key is pressed on a wireless key. Contact your installer to
have this programmed. The Master Code cannot use Bell Squawk attribute, but is required to
enable it for other codes.
NOTE: This feature cannot prevent the Arm/Disarming squawks from being generated if an
access code assigned to a wireless key is manually entered at a keypad.
Erasing an Access Code
To erase a code, select the code and enter as the first digit. If is entered, the system
will delete the code (including the associated proximity tag) immediately and the user will be
returned to select another code.
User Function Commands
Disarm the system then enter [Master Code]. The command is used to gain
access to the following list of Master functions of the system:
[1] Time and Date - Enter 4 digits for 24hr System Time (HH-MM). Valid entries are 00-23 for
the hour and 00-59 for minutes. Enter 6 digits for the Month, Day and Year (MM-DD-YY).
[2]-[3] For Future Use.
[4] System Test - The system’s Bell Output - 4 seconds (2 seconds medium volume, 2 seconds
high volume), keypad lights, back-up battery pack and communicator are tested.
[5] Enable DLS / Allow Remote System Service - If enabled, the installer will be able to
access Installer Programming remotely using DLS (Downloading Software). This function pro-
vides a window for telephone ring detection by the alarm system. The DLS window will remain
open for 6 hours, during which time the installer will be able to enter DLS an unlimited number of
times. After the 6-hr window has expired, access to programming via DLS will be unavailable
until the window is re-opened.
[6] User Call-up - If enabled by the installer, the panel will make 1 attempt to call the download-
ing computer. The downloading computer must be waiting for the panel to call before down-
loading can be performed.
[7] For Future Use.
[8] User Walk Test - Allows the user to enter the Walk Test mode. See Walk Test on page 11.
[9] Late to Open Enable/Disable - This function enables or disables the Late to Open time pro-
grammed in [0].
[0] Late to Open Time of Day - This function is used to program the time setting enabled in [9].
Changing Brightness/Contrast
When this option is selected, the keypad will allow you to scroll through 4 brightness levels and
10 contrast levels.
1. Press [Master Code].
2. Use the buttons to scroll to either Brightness Control or Contrast Control.
3. Press to select the setting you want to adjust.
4. a) ‘Brightness Control’: There are 4 backlighting levels. Use the buttons to scroll to
the desired level.
b) ‘Contrast Control’: There are 10 different display contrast levels. Use the buttons
to scroll to the desired contrast level.
5. To exit, press .
Changing the Buzzer Level
When this option is selected, the keypad will allow you to scroll through 21 different buzzer lev-
els. A level of 00 disables the buzzer.
1. Press [Master Code].
2. Use the buttons to scroll to Buzzer Control.
3. There are 21 different levels, use the buttons to scroll to the desired level.