- 1 . On your hard drive, locate the laptop’s IP address. Retrieve the number of the listening port; this is assigned by the application. You should also have on hand the Communicator’s phone number.
- 2 . Using this phone number send the Communicator an 18-digit SMS text message. This SMS text message is to be configured as: ! + IP address + Port number, without stops or spaces (e.g. !11122233344412345). Note that if you intend to use a port numbe...
- 3 . With an existing installation of DLS IV downloading software on your laptop, you now have the ability to program the Communicator using the GUI on the screen. See Options on page 23 for detailed programming information. Also, please refer to your...
- Models
- Features
- Technical Specifications
- Ratings
- Compatibility
- Table 2: Compatible Receivers and Control Panels
- INSTALLING THE GSM / ETHERNET COMMUNICATOR
- 1 . Wire the telephone line, if available.
- 2 . Wire the PC9155 panel (but not the Communicator).
- 3 . Turn on the PC9155 panel. Program the panel’s telephone number, account code, format, GS / IP module enable, and the communication path priority (i.e. PSTN > Ethernet > GRPS).
- 4 . Turn off the panel.
- 5 . Wire the Communicator through the PC-Link.
- 6 . Proceed to CONNECT 24 Activation Information below.
- 7 . Turn on the panel. Wait for the initialization of the Communicator.
- 1 . Assemble the Communicator
- 2 . Install the Communicator module into the Cabinet
- 3 . Turn on the panel and check signal strength.
- 1 . Attach the Communicator to the inside of the PC9155 control panel cabinet if not already present.
- 2 . Turn on the PC9155 cabinet and check signal strength.
- 1 . Program the hexadecimal digits (DCAA) in the telephone number that will be used to contact the GSM / Ethernet Communicator (panel Options 301, 302, 303, ‘Telephone Phone Number Programming’).
- 2 . In Option 350, program the communication format as SIA FSK.
- 3 . In Options 351 through Option 376, program the call direction sub-options for the phone number being used to communicate using the GSM / Ethernet Communicator.
- 4 . Option 382, sub-option 5 must be set to ON.
- STATUS LEDs
- Trouble Status LED
- Network Connection Status LED
- Signal Strength LEDs
- Table 4: Radio Signal Strength
- 1 . Turn off the power to the Communicator by physically unplugging the unit from its power supply.
- 2 . Attach one end of the extension cable to the Communicator and the other end to the antenna itself.
- 3 . Reattach the power supply and turn on.
- 4 . Move the antenna around until you have received a strong signal.
- 5 . Mount the antenna bracket at that location.
- 1 . Locate the set of five vertically aligned pins in the middle of the Communicator board.
- 2 . Counting from the bottom, the first three pins are reserved for future use. You may discount these.
- 3 . The final two pins require a jumper in order to reset the hardware values.
- 4 . Turn off power to the Communicator.
- 5 . Apply the jumper to the two pins.
- 6 . Turn on power to the Communicator. Wait for ten seconds.
- 7 . Remove the jumper from the pins.
- Table 5: Communicator Troubles on a 9155 Panel
- Table 4: Radio Signal Strength
- Options
- Programming Worksheets
26
address must be entered as four 3-digit entries (e.g. 192.168.1.101). Each 3-digit segment of the address must be within a valid
range of 000 to 255.
Option 104: Ethernet Receiver 1 Local Port
Default (3060)
You can use this option to set the value of the local outgoing port. You can set the value of this port in case your installation is
located behind a firewall and must be assigned a particular port number as determined by your network administrator. Valid entries
range from 0000 to FFFF hexadecimal.
Option 105: Ethernet Receiver 1 Remote Port
Default (3061)
Option 105 determines the port of Ethernet receiver 1. Valid entries range from 0000 to FFFF hexadecimal.
Ethernet Receiver 2 Options
Option 111: Ethernet Receiver 2 Account Code
Default (0000FFFFFF)
The account code is used by the central station to distinguish between transmitters. This account code is used when transmitting
signals to the central station receiver. Signals received from the control panel will use the control panel account number. Valid
entries will range from 0000000000 to FFFFFFFFFF hexadecimal.
Option 112: Ethernet Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the Account Code to to identify the Communicator module as the central station. Valid entries
range from 000000 to 0FFFFF hexadecimal.
Option 113: Ethernet Receiver 2 Address
Default (0.0.0.0)
Enter the Ethernet receiver 2 IP address. This information will be provided by your central station. Note that when a valid address
has been entered, the Ethernet will be considered to be enabled and will communicate events over the Ethernet channel. The
address must be entered as four 3-digit entries (e.g. 192.168.1.101). Each 3-digit segment of the address must be within a valid
range of 000 to 255.
Option 114: Ethernet Receiver 2 Local Port
Default (3065)
You can use this option to set the value of the local outgoing port. You can set the value of this port in case your installation is
located behind a firewall and must be assigned a particular port number as determined by your network administrator. Valid entries
range from 0000 to FFFF hexadecimal.
Option 115: Ethernet Receiver 2 Remote Port
Default (3061)
Option 115 determines the port of Ethernet receiver 2. You can set the value of this port in case your installation is located behind
a firewall, and must be assigned a particular port number as determined by your central station system administrator. Valid entries
range from 0000 to FFFF hexadecimal.