User's Manual
1
INTRODUCTION
The GS3060 is a backup wireless communicator that sends alarm system information to a System III
or System II receiver through a GSM/GPRS wireless network.
Features
• Compatible with any listed panel that supports a 4 or 10-digit Contact ID
• Simulates land line
• Switches automatically to GSM network in the event land line trouble (line down)
• GSM Signal Indicator
• 4 programmable outputs
• Houses 12V - 1.2 Ah battery
• Case Tamper Output
• Land-line Overvoltage Protection
• Dual-Band GSM Radio
• 4 input lines
• GPRS/Internet communication with Sur-Gard System III / II
• PTM Feature 4 phone numbers programmable for Contact ID Dialer
Technical Specifications
The input voltage to the GS3060
can be drawn from the Control Panel or provided by an external UL
Listed power supply rated for the application (external power-limited source).
Ratings
Power Supply RatingsPower Supply Ratings
Power Supply RatingsPower Supply Ratings
Power Supply Ratings
Input Voltage: ............................................................................................ 9 - 14V
DC (13.8VDC typical)
Current: .............................. 120mA* (JP3 - OFF and internal battery required) or 500mA* (JP3 ON)
* Plus any current drawn from the GS3060 AUX+ terminal
Battery: ......................................................................... sealed, rechargeable type, rated 12V/1.2Ah
Recharging current: ................................................................................................................... 50mA
CurCur
CurCur
Cur
rr
rr
r
ent consumptionent consumption
ent consumptionent consumption
ent consumption
Standby current: ...................................................................................................................... 120mA
Alarm (Transmitting) current: ................................................................................................... 450mA
PGM outputs: ....................................................................................... 4, open collector, rated 50mA
Operating frequency: ................................................................................................... 850/1900MHz
Antenna Gain: ............................................................................................................................ 1.5dB
EnvirEnvir
EnvirEnvir
Envir
onmental specificationsonmental specifications
onmental specificationsonmental specifications
onmental specifications
Operating temperature: .................................................................................. 0°C-49°C (32°F-120°F)
Humidity: ................................................................................. 93%RH Maximum (Non-Condensing)
Mechanical specificationsMechanical specifications
Mechanical specificationsMechanical specifications
Mechanical specifications
Metal enclosure, painted; dimensions: ...................... 138mm x 224mm x 55mm / 5.4” x 8.8” x 2.2”
Weight (without battery): ................................................................................................. 900g / 3.2 oz
Internal Event Buffer (communications): ................................................... 256 Events (not viewable)
Maximum loop resistance of line between the device connected in series on T1/R1: ........... 1Kohm
This equipment GS3060 is fixed and shall be installed by Service Persons only (Service Person is defined as a person
having the appropriate technical training and experience necessary to be aware of hazards to which that person may
be exposed in performing a task and of measures to minimize the risks to that person or other persons). It shall be
installed and used within an environment that provides the pollution degree max 2, over voltages category II, in non-
hazardous, indoor locations only. This manual shall be used with the Installation Manual of the alarm control panel.
All instructions specified within that manual must be observed.