• W A R N I N G • This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. Installation Manual RF5132-433 Version 5.
Table of Contents C O N T Introduction ................................................ 1 1.1 How to Use this Manual ....................... 1 1.2 Specifications and Features ................ 1 1.3 Compatible Wireless Devices .............. 2 RF5132-433 Set Up & Wiring ..................... 3 2.1 Unpack the RF5132-433 ...................... 3 2.2 Choose a Mounting Location for the RF5132-433 ......................................... 3 2.3 Connect the RF5132-433 Receiver ...... 3 3.
Introduction S E C T I O N 1 This manual describes how to install, program and maintain the RF5132-433. Before you install the RF5132-433 module, you should complete the following steps in your system installation: 1. Plan the installation and wiring of the security system (see your system Installation Manual). 2. Install the control panel, and install and enroll at least one keypad to use for programming. 3. Install and enroll any hardwired zone expander modules (PC5108) you plan to use.
I N T R O D U C T I O N 1.3 Compatible Wireless Devices Please refer to the Instruction sheets of the following devices for more information. The RF5132-433 v5.
RF5132-433 Set Up & Wiring S E C T I O N 2 This section describes how to set up and wire the RF5132-433 module. 2.1 Unpack the RF5132-433 Check that the following parts are in your RF5132-433 package: • RF5132-433 PCB • Hardware for mounting the cabinet • RF5132-433 plastic cabinet 2.2 Choose a Mounting Location for the RF5132-433 NOTE: Mount the RF5132-433 receiver and wireless devices after you have done placement tests with the wireless devices (see sections 5.1 and 5.2).
Receiver Programming S E C T I O N 3 Enroll & Program Devices This section describes how to enroll and program: • wireless devices using zones (WLS904PL-433, WLS906-433, WS4916, WLS912L-433, WLS914-433, WS4938, WS4955 and WLS925L-433) • wireless keys (WLS919-433, WS4939) For more information on these devices, read the instruction sheet included with each device. 3.
W I R E L E S S D E V I C E S zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-12 and zones 13-16). None of the zones assigned to a PC5108 module may be used for wireless devices. For more information on zone assignment, consult your system Installation Manual. 4. Enter the device ESN. The entry must be 6 digits. 5. The device is now enrolled on the system. Record the serial number and the assigned zone number in the programming worksheets in the back of this manual. 6.
W I R E L E S S D E V I C E S if desired. After the functions are programmed, when you press and hold one of the four buttons for one second, the system will execute the programmed function. For systems using partitions (PC5020/PC1616/PC1864/P-8+/PC501X/P832/P832DL only): All wireless keys assigned to Partition 1 will have the four functions programmed in section [61]. All wireless keys assigned to Partition 2-8 will have the four functions programmed in section [62-68].
Other Programming S E C T I O N 4 4.1 Program Zones and Partitions Now that you have enrolled the wireless devices, you should complete all zone programming on the system.
O T H E R P R O G R A M M I N G If the RF5132-433 module does not show on the keypad, one of the following conditions may be present: • the module is not connected properly to the Keybus • there is a problem with the Keybus wiring run • the module does not have enough power • no devices have been enrolled on the RF5132-433 4.3 Enable Supervision of Wireless Zones NOTE: (for PC5010 v1.
O T H E R P R O G R A M M I N G 3. Enter section [93]. Enter the 2-digit number of the RF Jam Detect zone ([01] to [32]) in the programming section. 4. Disable supervision for the RF Jam detect zone by turning the relevant option off in section [82], [83], [84] or [85]. (See section 4.3 for more information.) 5. RF jamming detection is now enabled. To exit Installer programming, press [#].
Testing & Mounting S E C T I O N 5 5.1 Test the Reception of Wireless Devices It is very important to test the proposed placement of each wireless device before it is mounted. Following these steps will test the signal strength between the RF5132-433 and the wireless devices. You can test all of the devices together (global placement testing) or test each device individually. To test all the devices together, see ‘Testing All Wireless Devices Together’ below.
T E S T I N G & M O U N T I N G WLS909-433/WLS919-433: Press any function key at several different locations. WLS912-433: Press and hold the test mode tab for 5 seconds. Release the test mode tab. The keypad will display the test result. Read the test results at the keypad: Result LED Keypad LCD Keypad Buzzer/Bell Good Light 1 On Steady “Good” 1 Beep/Squawk Bad Light 3 On Steady “Bad” 3 Beeps/Squawks Activate the device until you get 3 ‘good’ results in a row.
5.2 Mount the RF5132-433 and Wireless Devices When you have tested reception of the RF5132-433 with all the wireless devices (see section 5.1) and you have a good mounting location, mount the RF5132-433: 1. Pull the Keybus wires through the hole at the bottom of the cabinet. 2. Mount the cabinet securely to the wall. Mount the Devices If you have conducted the placement test described in section 5.1 and got 3 ‘good’ results in a row for each device, you can mount the wireless devices.
Additional Notes S E C T I O N 6 6.1 Trouble Conditions The control panel always watches for possible trouble conditions. If a trouble condition occurs, the keypad “Trouble” light will turn on and the keypad will beep. Press [*][2] to display the trouble conditions. The following trouble conditions apply to the RF5132-433 and/or any enrolled devices. General System Tamper - This trouble is generated when the RF5132-433 detects an RF Jamming condition.
Troubleshooting S E C T I O N 7 The RF5132-433 v5.0 features two LEDs to help troubleshoot the operation of the unit. The LEDs will indicate if the signal received is from an enrolled device or not. • The green LED will flash when receiving a signal from an enrolled device. • The red LED will flash when receiving a signal from a non-enrolled device. For more precision, when the panel is in placement test mode, the green LED will only flash for the specific serial number entered.
Programming Worksheets S E C T I O N 8 [804] 5132--433 Wireless Expansion Programming • 6-digit entry is required. See Section 3.1 “A note on Electronic Serial Numbers” for details on programming 6-digit serial numbers.
P R O G R A M M I N G W O R K S H E E T Wireless Key Serial Numbers Default = 000000 [41] Key 01 l_____l_____l_____l_____l_____l_____l [42] Key 02 l_____l_____l_____l_____l_____l_____l [43] Key 03 l_____l_____l_____l_____l_____l_____l [44] Key 04 l_____l_____l_____l_____l_____l_____l [45] Key 05 l_____l_____l_____l_____l_____l_____l [46] Key 05 l_____l_____l_____l_____l_____l_____l [47] Key 07 l_____l_____l_____l_____l_____l_____l [48] Key 08 l_____l_____l_____l_____l____
P R O G R A M M I N G W O R K S H E E T Wireless Key Options Partition 1 Wireless Key Options [61] Function Key 1 03 l____l____l Function Key 3 27 l____l____l l____l____l Function Key 4 30 l____l____l Partition 2 Wireless Key Options 03 [62] Function Key 1 l____l____l Function Key 3 27 l____l____l l____l____l Function Key 4 30 l____l____l Partition 3 Wireless Key Options 03 [63] Function Key 1 l____l____l Function Key 3 27 l____l____l l____l____l Function Key 4 30
P R O G R A M M I N G W O R K S H E E T S Supervision [81] Wireless Supervisory Window l____l____l Default = 96 The window is programmed in 15 minute increments. The default programming is 96 (x 15minutes), which is equal to 24 hours. Valid entries are (32) - (96), equal to 8 - 24 hours.
P R O G R A M M I N G W O R K S H E E T l________l Option 5 Zone 21 Supervision enabled Disabled l________l Option 6 Zone 22 Supervision enabled Disabled l________l Option 7 Zone 23 Supervision enabled Disabled l________l Option 8 Zone 24 Supervision enabled Disabled S [85] Zone Device Supervision Options (25-32) Default = ON Option ON Option OFF l________l Option 1 Zone 25 Supervision enabled Disabled l________l Option 2 Zone 26 Supervision enabled Disabled l
Guidelines for Locating Smoke Detectors A PS PE CE TN I DO IN X 9 A Experience has shown that all hostile fires in family living units generate smoke to a greater or lesser extent. Experiments using typical fires in family living units indicate that detectable quantities of smoke precede detectable levels of heat in most cases. In existing homes, NFPA Standard 72 requires that a smoke detector be installed outside each sleeping area and on each additional story of the family unit.
WARNING Please Read Carefully Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible. There are circumstances, however, involving fire, burglary, or other types of emergencies where it may not provide protection.
FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception.