Installation Manual

Skyroute CL3050 Universal Wireless Communicator
22
Event Reporting Code Event Reporting Code
SIA
Contact
ID
SIA
Contact
ID
Zone Tamper Alarms Zone Tamper Restores
Burglary Zone BTXX E380 Burglary Zone BJXX R380
Fire Zone FTXX E373 Fire Zone FJXX R373
Panic Zone PTXX E380 Panic Zone PJXX R380
Technical Zone UTXX E380 Technical Zone UJXX R380
Gas Zone* GTXX E380 Gas Zone* GJXX R380
High Temp Zone* KTXX E380 High Temp Zone* KJXX R380
Medical Zone* MTXX E380 Medical Zone* MJXX R380
Emergency Zone QTXX E380 Emergency Zone QJXX R380
Water Level Zone* WTXX E380 Water Level Zone* WJXX R380
Low Temp Zone* ZTXX E380 Low Temp Zone* ZJXX R380
Sprinkler Zone* STXX E373 Sprinkler Zone* SJXX R373
Hold-up Zone HTXX E380 Hold-up Zone HJXX R380
Trouble Zone UTXX E380 Trouble Zone UJXX R380
Generic Zone Events System Events
Generic Burglary BA98 E130
98
Input Supply Fail
Trouble
YP00 E312
Generic Fire FA98 E110
98
Input Supply Fail
Restore
YQ00 R312
Generic Panic Zone PA98 E120
98
Low Battery Trouble YT00 E302
Generic Supervisory UA98 E140
98
Low Battery Restore YR00 R302
Skyroute CL3050
Tamper Alarm
TA00 E137
Skyroute CL3050
Tamper Restore
TR00 R137
PC5108 Tamper Alarm ES00 E330
PC5108 Tamper Restore EJ00 R330
PC5108 Supervisory
Trouble
ET00 E330
PC5108 Supervisory
Restore
ER00 R330
Periodic Test
Transmission
TXZZ E603
Periodic Test** RP00 E602
Periodic Test
with Trouble**
RY00 E608
TLM Trouble LT01 E351
TLM Restore LR01 R351
* Not for use in UL Installations.
** Only sent if a trouble zone is programmed.