5.4 UL Requirements
5.4.1 Grade A - Central Station Service, Residential Fire
and Burglary Installations
Programming [13] - Option 2 Test Rates must be “ON”.
Every 24 hours a check-in signal must be sent to the central
station. Refer to compatible Listed control unit’s installation
instructions for programming.
Dialing attempts must be programmed for 5 to 10 attempts.
Skyroute transmitter makes 3 attempts by default. Refer to
compatible Listed control unit’s installation instructions for
programming.
The response wait time, section [24] should be set to 09.
Alarm signals must be sent over both primary and secondary
communication paths -
1. Compatible Listed control unit’s land line to central sta-
tion (primary).
2. Skyroute transmission through Cellemetry to the clearing
house (Connect 24) (secondary).
DACT must be enabled for Listed compatible control unit.
5.4.2 Police Station Connect with Basic Line Security
Same as Grade A Central Station Installations.
5.4.3 Commercial Fire Installations
Same as Grade A Central Station Installations.
The BELL+ and BELL- terminals on the control panel shall
not power other devices. Refer to Compatible Listed control
unit installation instructions for wiring and programming.
5.4.4 Back-up Reporting Mode (03)
To be used only for UL/ULC residential Fire and Burglary
applications.
5.4.5 For ULC Installations
The redundant Communication mode (00) meets level 2 line
security requirements.