Installation Manual
16
[21] Generic Signal Timer
[22] Transmission Options
[23] Number of Attempts
[24] Response Wait Time
NOTE: For UL Installations, this section needs to be programmed as 09 for 90 seconds.
[90] Current Signal Strength Reading
BASIC PROGRAMMING COMPLETED
7.3 Advanced Programming
The following sub-sections (30 -78) have automatically been programmed. How they are programmed depends on how you default
the Skyroute (see Section 6.1). You may make changes if wanted.
Sub-sections [30] to [78]: If ’00’ is entered, reporting code is disabled.
If ‘FF’ is entered, default reporting code is enabled.
[30] Alarm Reporting Codes, Zones 1-16
[31] Alarm Reporting Codes, Zones 17-32
Default
1E I___I___I (number x 10 seconds in Hex)
Generic
Reporting
Full
Reporting
Option ON Option OFF
ON ON I___I Option 1 Alarms/Restoral Disabled
OFF ON I___I Option 2 Tamper/Restores Disabled
OFF ON I___I Option 3 Supervisory/Restores Disabled
OFF ON I___I Option 4 Low Battery/Restores Disabled
OFF OFF I___I Option 5 Openings/Closings Disabled
ON ON I___I Option 6 Maintenance/Restoral Disabled
OFF OFF I___I Options 7 & 8 For Future Use
Default
03 I___I___I___I 00-FF (HEX)
Default
19 I___I___I___I (number x 10 seconds in Hex)
I___I___I___I This section will show the most recent Skyroute signal strength as a percentage from 0-100%.
Generic
Reporting
Full
Reporting
Generic
Reporting
Full
Reporting
FF FF I___I___I Zone 1 Alarm FF FF I___I___I Zone 9 Alarm
FF FF I___I___I Zone 2 Alarm FF FF I___I___I Zone 10 Alarm
FF FF I___I___I Zone 3 Alarm FF FF I___I___I Zone 11 Alarm
FF FF I___I___I Zone 4 Alarm FF FF I___I___I Zone 12 Alarm
FF FF I___I___I Zone 5 Alarm FF FF I___I___I Zone 13 Alarm
FF FF I___I___I Zone 6 Alarm FF FF I___I___I Zone 14 Alarm
FF FF I___I___I Zone 7 Alarm FF FF I___I___I Zone 15 Alarm
FF FF I___I___I Zone 8 Alarm FF FF I___I___I Zone 16 Alarm
Generic
Reporting
Full
Reporting
Generic
Reporting
Full
Reporting
FF FF I___I___I Zone 17 Alarm FF FF I___I___I Zone 25 Alarm
FF FF I___I___I Zone 18 Alarm FF FF I___I___I Zone 26 Alarm
FF FF I___I___I Zone 19 Alarm FF FF I___I___I Zone 27 Alarm
FF FF I___I___I Zone 20 Alarm FF FF I___I___I Zone 28 Alarm
FF FF I___I___I Zone 21 Alarm FF FF I___I___I Zone 29 Alarm
FF FF I___I___I Zone 22 Alarm FF FF I___I___I Zone 30 Alarm
FF FF I___I___I Zone 23 Alarm FF FF I___I___I Zone 31 Alarm
FF FF I___I___I Zone 24 Alarm FF FF I___I___I Zone 32 Alarm
OPTIONAL