User's Manual
3
I N S T A L L A T I O N
1.4 Applying Power
Once all wiring is complete, apply power to the control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power specifications, see the control panel
Installation Manual
.
NOTE: Do not connect the power until all wiring is complete.
1.5 Enrolling the Keypad
Once all wiring is complete, you will need to enter a 2-digit number that tells the
system the partition and slot assignment of the keypad.
If your system has partitions, you will also need to assign the keypad to a partition
(1st digit).
The slot assignment (2nd digit) tells the panel which keypad slots are occupied. The
panel can then generate a fault when a keypad supervisory signal is not present.
There are eight available slots for keypads. RF5501-433 keypads are always
assigned to slot 1 by default. You will need to assign each keypad to its own slot (1
to 8).
NOTE: The RF5501-433 enrolls as two modules:
1 = keypad section of the RF5501-433
17 = receiver section of the RF5501-433
Enter the following at each keypad installed on the system:
1. Enter Installer Programming by pressing [*][8][Installer’s Code]
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter a two digit number to specify the partition and slot assignment.
NOTE: If your system does not have partitions, enter [1] for the first digit.
1st digit Enter 0 for Global Keypad, 1-8 for keypad partition
Enter 1 for Partition 1 Keypad
Enter 2 for Partition 2 Keypad
2nd digit Enter 1 to 8 for Slot Assignment
5. Press the [#] key twice to exit programming.
6. After assigning all keypads, perform a supervisory reset by entering [*][8][Installer’s
Code][902]. The panel will now supervise all assigned keypads and enrolled
modules on the system.
To review which modules the control panel is currently supervising:
1. Enter [✱][8][Installer’s Code]
2. Enter [903] to display all modules. On the
RF5501-433 keypad,
11
11
1 and
11
11
1
77
77
7 will scroll on
the keypad to indicate that the
RF5501-433 is present on the system.
11
11
1 designates
the keypad section, and
1717
1717
17 is used to show the receiver section is also supervised.
If using an LCD5501Z keypad, scroll until the module name appears on the display.
3. To exit press [#].