User's Manual
Table Of Contents
- Table of Contents
- 1 Introduction
- 2 Installation, Testing & Factory Defaults
- 3 Controls and Indicators
- 4 Power up Sequence
- 5 System Programming
- 6 Programming Descriptions
- 7 Programming Worksheets
- Glossary of Terms
- Skyroute CL3050 Quick Start:
- Note: Before you start, you must be enrolled with CONNECT 24 as an authorized installer to activa...
- STEP 1 - SELECT BEST LOCATION (See Section 2.1)
- Connect the Skyroute transceiver to a 7 Ah battery, as described in Section 2.1. Determine the be...
- STEP 2 - CONNECT NECESSARY WIRING (See Section 6)
- Mount the Skyroute, determine the desired mode of operation and connect the appropriate control p...
- STEP 3 - PROGRAM (See Section 5)
- If the default programming must be changed, connect a PowerSeries keypad as shown in Section 5 an...
- STEP 4 - ACTIVATE (See Section 2.1)
- Call the Connect 24 Voice Response Unit (VRU) at the toll free number provided with your Dealer C...
- STEP 5 - TEST (See Section 2.2)
- Once activated, send two signals to your central station to confirm proper operation.
- YOUR SKYROUTE INSTALLATION IS NOW COMPLETE.
- ALL OTHER PROGRAMMING SECTIONS IN THIS MANUAL ARE OPTIONAL.
- Appendix A: Reporting Codes
1 Introduction
1
1 Introduction
The Skyroute CL3050 is a standalone wireless communicator that sends alarm system infor-
mation to
Connect 24
. Connect 24 then forwards this information to the central station.
The Skyroute CL3050 automatically configures itself on power up to one of three opera-
tional modes or; if it is connected to a keypad, in the programming mode. The Skyroute
CL3050 is pre programmed with the most commonly used settings for quick installation. If
required the default options can be custom programmed.
Mode 1: Bell Follower
If the Skyroute CL3050 does not detect a keypad or PC5108 expander card dur-
ing the first 15 seconds of power up, then mode 1 or 2 can be selected by press-
ing the enroll button. The red LED indicates Mode 1 and the yellow LED indicates
mode 2. In Mode 1, the Skyroute CL3050 monitors the
Bell Output
of the con-
trol panel. The system identifies the Bell Output cadence and transmits the corre-
sponding Fire or Burglar alarm reporting code to
Connect 24
.
Refer to the appropriate
control panel Installation Manual.
Mode 2: 2-Zone
Panel
If Mode 2 is selected during power up the system will configure itself for 2 zone,
stand alone operation with normally closed loops.
Mode 3: 8-Zone Panel
If the Skyroute CL3050 detects a PC5108 expander card on power up it will auto-
matically configure itself for 8-zone standalone operation with normally closed
loops.
Programming Mode
If the Skyroute CL3050 detects a keypad on power up it will go into the program-
ming mode. Programming mode allows the installer to custom program system
options. Refer to Section 5, Programming Descriptions; and Section 6, Program-
ming Worksheets for programming options and default settings.
Note:
The only method of entering the Programming Mode is to power-down the unit,
connect a PowerSeries keypad to the Keybus terminals, then reapply power to
the Skyroute CL3050.
Figure 1