User's Manual
Table Of Contents
- Table of Contents
- 1 Introduction
- 2 Installation, Testing & Factory Defaults
- 3 Controls and Indicators
- 4 Power up Sequence
- 5 System Programming
- 6 Programming Descriptions
- 7 Programming Worksheets
- Glossary of Terms
- Skyroute CL3050 Quick Start:
- Note: Before you start, you must be enrolled with CONNECT 24 as an authorized installer to activa...
- STEP 1 - SELECT BEST LOCATION (See Section 2.1)
- Connect the Skyroute transceiver to a 7 Ah battery, as described in Section 2.1. Determine the be...
- STEP 2 - CONNECT NECESSARY WIRING (See Section 6)
- Mount the Skyroute, determine the desired mode of operation and connect the appropriate control p...
- STEP 3 - PROGRAM (See Section 5)
- If the default programming must be changed, connect a PowerSeries keypad as shown in Section 5 an...
- STEP 4 - ACTIVATE (See Section 2.1)
- Call the Connect 24 Voice Response Unit (VRU) at the toll free number provided with your Dealer C...
- STEP 5 - TEST (See Section 2.2)
- Once activated, send two signals to your central station to confirm proper operation.
- YOUR SKYROUTE INSTALLATION IS NOW COMPLETE.
- ALL OTHER PROGRAMMING SECTIONS IN THIS MANUAL ARE OPTIONAL.
- Appendix A: Reporting Codes
6 Programming Descriptions
13
[15] System Time
All Modes
When the time and day have been programmed, the values are saved and are
used as the current time and day whenever the Skyroute CL3050 does a power
up. Time and day programming is only required if the installer desires the Sky-
route CL3050 to test transmit at a specific time and/or day. There is no "loss of
time" trouble on the Skyroute CL3050.
Default -
0000 - 2359
Note
If AC Power is detected, it will be used to provide the time base for the
internal clock. If AC power is not detected the internal clock will auto-
matically use the crystal time base.
[16] System Day of the Week
All Modes
See section [15].
Option 1.
Default -
ON
Option 2 - 8.
Default -
OFF
[17] Test Transmission Time
All Modes
When the Skyroute CL3050 is powered up for the first time, or after a default
reset; it will check if the test transmission time and day are programmed. If they
are not, a random time (0000 - 2359) will be programmed into this location. The
Skyroute CL3050 will randomly generate this value.
Note:
Due to traffic volume, when selecting test transmission times, select a
time that is not on the :30 minute mark (e.g., 02:24, 04:07)
.
[18] Test Transmission Day
All Modes
When the Skyroute CL3050 is powered up for the first time, or after a default, it
will check if the test transmission time and day are programmed. If they are not,
a random day (Sunday-Saturday) will be programmed into this location. The Sky-
route CL3050 will randomly generate this value. Because one test transmission
weekly is the most common configuration, this will allow the installer to setup
the Skyroute CL3050 without keypad programming.
Option 1-8.
Default -
[Random]
- One only will be enabled.
[20] Transmission Options
All Modes
When the following options are enabled the reporting codes listed in Appendix A
are sent to
Connect 24
.
Options 1, 2 - Zone Alarm/Zone Alarm Restores
Modes 2, 3
When a zone is violated or restored, the reporting codes listed in Appendix A will
be sent.
Note:
If generic reporting is enabled and multiple alarms occur during the
delay programmed in Section [23], only one alarm reporting code will
be sent.
Note:
Zone alarm restorals enabled with generic zone reporting enabled can
cause unpaired events to be sent to Connect 24.
Option 1.
Default -
ON,
Option 2.
Default -
OFF