4.1 PC5102 PGM Outputs
The PC5102 433 has two on-board Form C Relay PGM outputs. Each of these can
be individually programmed to either:
1. Follow main panel PGM outputs 1 to 14.
NOTE: Please refer to your System Installation Manual for available PGM outputs.
NOTE: If the PC5102-433 is connected to the following panels, PC580/PC1555 all
versions, PC5010 v1.x, WSS5010 1.0, 2.1, PC1565-2P v2.2 or PC5016 v1.x, the PC5102
PGM outputs cannot be programmed to follow main panel PGM outputs 1 or 2.
2. Activate for a programmable amount of time when a data packet is received
from a wireless key programmed with option 31 or 32 and the PGM output
programming section [91] or [92] is programmed with option 15 (PC5102
PGM pulse). The default for the two PGM activation time programming
sections [94] and [95] is 00 minutes and 05 seconds.
3. Toggle state when a data packet is received from a wireless key programmed
with option 31 or 32 and the PGM output programming section [91] or [92] is
programmed with option 16 (PC5102 PGM Toggle).
4.2 Enable PC5102-433 Supervision
The control panel will supervise the PC5102-433 receiver via the Keybus after at least
one key has been enrolled on the module (see section 3.2 “Enrolling Wireless Keys”).
To activate module supervision, after you enroll the first key(s):
1. Exit and then re-enter installer’s programming.
2. Enter programming section [902]. Wait approximately one minute.
3. To exit press [#].
The system will generate a General System Supervisory trouble if the module is
removed from the Keybus. If you need to remove the PC5102-433 module from an
existing system, you will have to disable supervision of the PC5102-433.
NOTENOTE
NOTENOTE
NOTE: Deleting all wireless keys from the PC5102-433 or defaulting the PC5102-433
will cause a supervisory fault.
To disable PC5102-433 supervision:
1. Disconnect the PC5102-433 from the Keybus
2. Enter [✱][8][Installer Code].
3. Enter [902]. The control panel will clear all supervision and re-scan the system for
connected modules. The scan will take approximately one minute.
4. To exit press [#].
To review which modules the control panel is currently supervising:
1. Enter [✱][8][Installer’s Code]
2. Enter [903] to display all modules. On LED keypads, light [17] will indicate
that the PC5102-433 is present on the system. On LCD keypads, scroll until
the module name appears on the display.
3. To exit press [#].
S E C T I O N 4
Other Programming