•WARNING• This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. Installation Manual PC5102-433 Version 1.
FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this equipment. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception.
Table of Contents C O N T Introduction 1.1 1.2 1.3 1.4 3 5 8 10 Test the Reception of Wireless Keys ................................................... 10 Mount the PC5102-433 ....................................................................... 10 Additional Notes 6.1 6.2 1 PC5102 PGM Outputs .......................................................................... 8 Enable PC5102-433 Supervision .......................................................... 8 PC5102-433 Software Default .......
WARNING Please Read Carefully Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible. There are circumstances, however, involving fire, burglary, or other types of emergencies where it may not provide protection.
Thank you for purchasing the PC5102-433 Wireless Receiver. This product will allow you to connect up to 8 Wireless Keys to the PC580, PC1555, and the Power Series control panels. The PC5102-433 uses 433 MHz. It provides on-board PGMs and features a 6-digit serial number for all wireless devices. These new serial numbers include hexadecimal digits. Please read Section 3.1 “A note on Electronic Serial Numbers (ESN)” for more information on enrolling 6-digit devices.
Introduction S E C T I O N 1 This manual describes how to install, program and maintain the PC5102-433. Before you install the PC5102-433 module, you should complete the following steps in your system installation: 1. Plan the installation and wiring of the security system (see your system Installation Manual). 2. Install the control panel, and install and enroll at least one keypad to use for programming. Program the PC5102-433 from a system keypad or using DLS-3 v1.3 with the PC5102433 v1.
I N T R O D U C T I O N 1.3 Compatible Wireless Keys Please refer to the instruction sheets of the following keys for more information. The PC5102-433 v1.X can receive signals from the following keys: • WLS909-433 Wireless Key • WLS919-433 Wireless Key 1.4 Batteries The WLS909-433 uses three A-76 batteries and the WLS919-433 uses two CR2032 Lithium batteries.
PC5102-433 Set Up & Wiring S E C T I O N 2 This section describes how to set up and wire the PC5102-433 module. 2.1 Choose a Mounting Location for the PC5102-433 NOTE NOTE: Mount the PC5102-433 receiver and wireless keys after you have done placement tests with the wireless keys (see sections 5.1 and 5.2).
S E T U P & W I R I N G 2.4 Connect the PC5102-433 Receiver CAUTION: Remove all power from the system while connecting modules to the Keybus. Connect the PC5102-433 to the four-wire Keybus of the control panel according to the following diagram. Control Panel YEL BLK GRN RED RED BLK YEL GRN KEYBUS TO PC5102 After you have completed the wiring, reconnect the power to the security system. Now that you have wired the PC5102-433, you should enroll and program the wireless keys.
Enrolling Wireless Keys S E C T I O N 3 This section describes how to enroll wireless keys (WLS909-433 and WLS919-433). For more information on these keys, read the instruction sheet included with each key. 3.1 A Note about Electronic Serial Numbers An electronic serial number (ESN) is printed on the back of each wireless key. ESNs are used to enroll the wireless keys with the PC5102-433 receiver.
W I R E L E S S D E V I C E S For systems using partitions (PC5020 / PC501X only): all wireless keys assigned to Partition 1 will have the four functions programmed in section [61]. All wireless keys assigned to Partition 2-8 will have the four functions programmed in section [62-68]. For example, if function button 1 in Section [61] is programmed for Stay arming, then pressing the first button on wireless keys assigned to Partition 1 will Stay arm Partition 1.
W I R E L E S S D E V I C E S Command Output Activation NOTE NOTE: The Identified Wireless Key Command Output Activation feature is only available with the PC5020, PC501X, PC1555, PC5008 and PC580 v2.0 and higher. To enable command output activation by wireless keys, ensure that: • The control panel is v2.0 or higher • Program a valid access code for each key • Enable the PGM output attribute Requires Access Code for each PGM output programmed as [✱][7][1-4] in sections [141] to [154].
Other Programming S E C T I O N 4 4.1 PC5102 PGM Outputs The PC5102 433 has two on-board Form C Relay PGM outputs. Each of these can be individually programmed to either: 1. Follow main panel PGM outputs 1 to 14. NOTE: Please refer to your System Installation Manual for available PGM outputs. NOTE: If the PC5102-433 is connected to the following panels, PC580/PC1555 all versions, PC5010 v1.x, WSS5010 1.0, 2.1, PC1565-2P v2.2 or PC5016 v1.
O T H E R P R O G R A M M I N G If the PC5102-433 module does not show on the keypad, one of the following conditions may be present: • the module is not connected properly to the Keybus • there is a problem with the Keybus wiring run • the module does not have enough power • no keys have been enrolled on the PC5102 NOTE: The PC5102-433 will be supervised and displayed as a PC5132. 4.
Testing & Mounting S E C T I O N 5 5.1 Test the Reception of Wireless Keys It is very important to test each wireless key. Following these steps will test the signal strength between the PC5102-433 and the wireless key. Testing Individual Wireless Keys To ensure that the PC5102-433 receiver is receiving transmissions from these devices, use the function keys on the WLS909-433/WLS919-433 at several different points in the installation. 5.
Additional Notes S E C T I O N 6 6.1 Trouble Conditions The control panel always watches for possible trouble conditions. If a trouble condition occurs, the keypad “Trouble” light will turn on and the keypad will beep. Press [✱][2] to display the trouble conditions. The following trouble conditions apply to the PC5102-433 and/or any enrolled wireless keys. General System Tamper - This trouble is generated when the PC5102-433 plastic cover is removed.
Troubleshooting S E C T I O N 7 1. When I enter the 2-digit zone number while adding a wireless device, the keypad gives me a long beep. You cannot enter ESNs unless a PC5102-433 wireless receiver is connected to the Keybus. See section 2 for instructions on setting up and wiring the PC5102-433 module. 2. I have entered the ESN for the wireless key but when I press the function keys, the panel does not perform the desired function. Check the following: • Ensure the ESN has been entered correctly.
Programming Worksheets S E C T I O N 8 [804] 5102-433 Wireless Expansion Programming • 6-digit entry is required. See Section 3.1 “A note on Electronic Serial Numbers” for details on programming 6-digit serial numbers.
P R O G R A M M I N G W O R K S H E E T S Wireless Key Options Partition 1 Wireless Key Options [61] Function Key 1 03 l____l____l Function Key 3 27 l____l____l Function Key 2 04 l____l____l Function Key 4 30 l____l____l l____l____l Function Key 3 27 l____l____l l____l____l Function Key 4 30 l____l____l l____l____l Function Key 3 27 l____l____l l____l____l Function Key 4 30 l____l____l Partition 2 Wireless Key Options [62] Function Key 1 03 Function Key 2
P [92] R O G R A I N G O R K Description Null (No Operation) Main Panel PGM1 Main Panel PGM2 PC5208 PGM3 PC5208 PGM4 PC5208 PGM5 PC5208 PGM6 PC5208 PGM7 PC5208 PGM8 PC5208 PGM9 PC5208 PGM10 PC5204 PGM11 PC5204 PGM12 PC5204 PGM13 PC5204 PGM14 PC5102 PGM Pulse (local) PC5102 PGM Toggle (local) S H E E T S PC5102 PGM1 Output Option l________l________l PC5102 PGM2 Output Option l________l________l PC5102 - PGM1 Output Activation Time Default 00 PGM1 Output Activation Time (Minutes) Defaul
Index I N A D E X F R factory default 9 frequency 1 function keys 5 removing device 9 module 8 B I S batteries replacing 11 type 2 buttons programming 5 individual placement test 10 interference 3 serial number 5 slot number wireless key 5 supervision DEOL 9 device 9 disable 8 module 8 window 9 add wireless key antenna 1 5 C connect Keybus 4 receiver 4 D default module 9 panel 9 delete device 9 devices 2 removing 9 distance from control panel 1 E electronic serial number 5 enroll PC5132
LIMITED WARRANTY Digital Security Controls Ltd. warrants the original purchaser that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use. During the warranty period, Digital Security Controls Ltd. shall, at its option, repair or replace any defective product upon return of the product to its factory, at no charge for labour and materials.
©2001 Digital Security Controls Ltd. Toronto, Canada 1-888-888-7838 • www.dsc.