Installation Manual
6
[3] ON = Keypad does not display time when zones are open
OFF = Keypad displays time when zones are open
5. When you are finished programming the clock options, press [#] to exit.
2.4 Alarms Displayed While Armed Option
You can disable the display of alarms on the keypad when the system is armed.
The display of alarms is enabled by default. To disable the display of alarms
when the system is armed, turn off section [6], option [5]:
1. Enter [*][8][Installer’s code]
2. Enter [000] to go to keypad programming
3. To turn the display of alarms on or off, enter section [6].
4. Turn option [5] on or off:
[5] ON = Alarms not displayed while system is armed
OFF = Alarms are always displayed while system is armed
5. When you are finished, press [#] to exit.
2.5 Emergency (Fire, Auxiliary, Panic) Key Options
You can enable or disable the Fire, Auxiliary and Panic keys at each keypad.
These keys are enabled by default. Please see your system’s
Installation
Manual
for more information on these keys and their options. To turn any of the
emergency keys on or off on the keypad:
1. Enter [*][8][Installer’s code]
2. Enter [000] to go to keypad programming
3. Enter section [7].
4. To turn the emergency key options on or off, press [1], [2], or [3]:
[1] ON = Fire key enabled
OFF = Fire key disabled
[2] ON = Auxiliary key enabled
OFF = Auxiliary key disabled
[3] ON = Panic key enabled
OFF = Panic key disabled
5. When you are finished, press [#] to exit.
2.6 Door Chime Options
You can program the LCD5501Z32-433 keypad to sound a tone when any
zone is opened or closed. There are two parts to the LCD5501Z32-433 door
chime programming:
• Program if the LCD5501Z32-433 will chime when zones are opened and/or closed.
• Program the type of sound the LCD5501Z32-433 will make when an individual
zone is opened or closed.
For the door chime feature to work, you will also need to turn on the Door Chime
attribute for each zone that will trigger the chime. This programming is done in
the control panel software. Refer to your control panel’s
Installation Manual
for
more information.
K E Y P A D P R O G R A M M I N G