Installation Manual
8
Receiver Programming
S E C T I O N 3
Enroll & Program Devices
This section describes how to enroll and program:
• wireless devices using zones (WLS904, WLS904P, WLS906, WLS907, WLS912,
WLS914 and WLS925L)
• wireless keys (WLS909, WLS929)
For more information on these devices, read the instruction sheet included with
each device.
3.1 A Note about Electronic Serial Numbers
An electronic serial number (ESN) is printed on the back of each wireless device.
ESNs are used to enroll the wireless devices with the LCD5501Z32-433 keypad.
In order to reduce the occurrence of wireless devices with the same serial number,
6-digit serial numbers are now printed on the back of each wireless device.
NOTE: 6-digit serial numbers are only supported on the following control panels:
PC5010 v2.x and higher, PC5015 v2.2, PC5008, PC1555 and PC580.
The 6-digit serial numbers include hexadecimal digits. For instructions on programming,
hexadecimal numbers, see your system
Installation Manual
, section 4: How to Program.
When connecting the LCD5501Z32-433 to a PC5010 or PC5015 v1.x panel, enter 5-
digit serial numbers only.
When connecting the LCD5501Z32-433 to a PC5010 v2.x, PC5015 v2.x, PC5008,
PC1555 or PC580 panel follow the instructions below.
Old Wireless Device ESNs
You can use older devices on all versions of the LCD5501Z32-433 keypad, even
though they only have a 5-digit ESN. When using older wireless devices:
Enter [0] + 5-digit ESN
3.2 Enroll Wireless Devices Using Zones (WLS904, WLS904P,
WLS906, WLS907, WLS912, WLS914, WLS925L)
Enroll wireless devices which use zones (universal transmitters, motion detec-
tors, smoke detectors, and panic pendants):
1. At a system keypad, enter [✱][8][Installer’s code] to go the installer’s
programming section.
2. Enter programming section [804].
3. Enter the 2-digit number corresponding to the zone the device is to occupy
([01] to [32]).
NOTE: Hardwired and wireless devices cannot be assigned to the same zone.
PC5108 zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-12
and zones 13-16). None of the zones assigned to a PC5108 module may be used
for wireless devices. For more information on zone assignment, consult your system
Installation Manual.
4. Enter the device’s ESN. The entry
must
be six digits. If an older device with a